Wide-range ELISA Kit for Glycated Hemoglobin A1c (HbA1c)
Glycosylated Hemoglobin; Hemoglobin A1c; Hb1c; HbAIc; HbAIc
- Product No.WEA190Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range12.35-1000ug/mL
- Sensitivityn/a
- Sample Typeplasma and erythrocyte lysates
- Download n/a
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 441
For more details, please contact local distributors!US$ 630
For more details, please contact local distributors! US$ 2835
For more details, please contact local distributors! US$ 5355
For more details, please contact local distributors! US$ 44100
For more details, please contact local distributors!
Specificity of the Wide-range ELISA Kit for Glycated Hemoglobin A1c (HbA1c)
This assay has high sensitivity and excellent specificity for detection of Wide-range Glycated Hemoglobin A1c (HbA1c).
No significant cross-reactivity or interference between Wide-range Glycated Hemoglobin A1c (HbA1c) and analogues was observed.
Recovery of the Wide-range ELISA Kit for Glycated Hemoglobin A1c (HbA1c)
Matrices listed below were spiked with certain level of recombinant Wide-range Glycated Hemoglobin A1c (HbA1c) and the recovery rates were calculated by comparing the measured value to the expected amount of Wide-range Glycated Hemoglobin A1c (HbA1c) in samples.
Matrix | Recovery range (%) | Average(%) |
EDTA plasma(n=5) | 89-96 | 93 |
Precision of the Wide-range ELISA Kit for Glycated Hemoglobin A1c (HbA1c)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Wide-range Glycated Hemoglobin A1c (HbA1c) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Wide-range Glycated Hemoglobin A1c (HbA1c) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Wide-range ELISA Kit for Glycated Hemoglobin A1c (HbA1c)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Wide-range Glycated Hemoglobin A1c (HbA1c) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
EDTA plasma(n=5) | 84-91% | 90-104% | 80-93% | 95-103% |
Stability of the Wide-range ELISA Kit for Glycated Hemoglobin A1c (HbA1c)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Wide-range ELISA Kit for Glycated Hemoglobin A1c (HbA1c)
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
Test principle of the Wide-range ELISA Kit for Glycated Hemoglobin A1c (HbA1c)
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Wide-range Glycated Hemoglobin A1c (HbA1c) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Wide-range Glycated Hemoglobin A1c (HbA1c) and unlabeled Wide-range Glycated Hemoglobin A1c (HbA1c) (Standards or samples) with the pre-coated antibody specific to Wide-range Glycated Hemoglobin A1c (HbA1c). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Wide-range Glycated Hemoglobin A1c (HbA1c) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Wide-range Glycated Hemoglobin A1c (HbA1c) in the sample.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Mus musculus (Mouse) | Applications (RESEARCH USE ONLY!) |
NPA190Mu01 | Native Glycated Hemoglobin A1c (HbA1c) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA190Mu01 | Polyclonal Antibody to Glycated Hemoglobin A1c (HbA1c) | WB; IHC; ICC; IP. |
WEA190Mu | Wide-range ELISA Kit for Glycated Hemoglobin A1c (HbA1c) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA190Mu | ELISA Kit for Glycated Hemoglobin A1c (HbA1c) | Enzyme-linked immunosorbent assay for Antigen Detection. |
MEA190Mu | Mini Samples ELISA Kit for Glycated Hemoglobin A1c (HbA1c) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA190Mu | Multiplex Assay Kit for Glycated Hemoglobin A1c (HbA1c) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA190Mu11 | ELISA Kit DIY Materials for Glycated Hemoglobin A1c (HbA1c) | Main materials for "Do It (ELISA Kit) Yourself". |