Mini Samples ELISA Kit for Matrix Metalloproteinase 2 (MMP2)

CLG4; CLG4A; MMP-II; MONA; TBE-1; PEX; Gelatinase A; 72kDa Gelatinase; 72kDa Type IV Collagenase

  • Mini Samples ELISA Kit for Matrix Metalloproteinase 2 (MMP2) Packages (Simulation)
  • Mini Samples ELISA Kit for Matrix Metalloproteinase 2 (MMP2) Packages (Simulation)
  • Mini Samples ELISA Kit for Matrix Metalloproteinase 2 (MMP2) Results demonstration
  • MEA100Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Mini Samples ELISA Kit for Matrix Metalloproteinase 2 (MMP2)

This assay has high sensitivity and excellent specificity for detection of Mini Samples Matrix Metalloproteinase 2 (MMP2).
No significant cross-reactivity or interference between Mini Samples Matrix Metalloproteinase 2 (MMP2) and analogues was observed.

Recovery of the Mini Samples ELISA Kit for Matrix Metalloproteinase 2 (MMP2)

Matrices listed below were spiked with certain level of recombinant Mini Samples Matrix Metalloproteinase 2 (MMP2) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Matrix Metalloproteinase 2 (MMP2) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-96 92
heparin plasma(n=5) 92-101 96

Precision of the Mini Samples ELISA Kit for Matrix Metalloproteinase 2 (MMP2)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Matrix Metalloproteinase 2 (MMP2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Matrix Metalloproteinase 2 (MMP2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Mini Samples ELISA Kit for Matrix Metalloproteinase 2 (MMP2)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Matrix Metalloproteinase 2 (MMP2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-95% 90-103% 81-95% 80-91%
heparin plasma(n=5) 78-103% 91-98% 84-98% 96-105%

Stability of the Mini Samples ELISA Kit for Matrix Metalloproteinase 2 (MMP2)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Mini Samples ELISA Kit for Matrix Metalloproteinase 2 (MMP2)

1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.

Test principle of the Mini Samples ELISA Kit for Matrix Metalloproteinase 2 (MMP2)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mini Samples Matrix Metalloproteinase 2 (MMP2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Mini Samples Matrix Metalloproteinase 2 (MMP2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mini Samples Matrix Metalloproteinase 2 (MMP2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mini Samples Matrix Metalloproteinase 2 (MMP2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA100Mu01 Recombinant Matrix Metalloproteinase 2 (MMP2) Positive Control; Immunogen; SDS-PAGE; WB.
APA100Mu01 Active Matrix Metalloproteinase 2 (MMP2) Cell culture; Activity Assays.
RPA100Mu02 Recombinant Matrix Metalloproteinase 2 (MMP2) Positive Control; Immunogen; SDS-PAGE; WB.
PAA100Mu01 Polyclonal Antibody to Matrix Metalloproteinase 2 (MMP2) WB; IHC; ICC; IP.
PAA100Mu02 Polyclonal Antibody to Matrix Metalloproteinase 2 (MMP2) WB; IHC; ICC; IP.
SEA100Mu ELISA Kit for Matrix Metalloproteinase 2 (MMP2) Enzyme-linked immunosorbent assay for Antigen Detection.
MEA100Mu Mini Samples ELISA Kit for Matrix Metalloproteinase 2 (MMP2) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA100Mu CLIA Kit for Matrix Metalloproteinase 2 (MMP2) Chemiluminescent immunoassay for Antigen Detection.
LMA100Mu Multiplex Assay Kit for Matrix Metalloproteinase 2 (MMP2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK