Mini Samples ELISA Kit for Hyaluronic Acid (HA)

Hyaluronan; Hyaluronate

  • Mini Samples ELISA Kit for Hyaluronic Acid (HA) Packages (Simulation)
  • Mini Samples ELISA Kit for Hyaluronic Acid (HA) Packages (Simulation)
  • Mini Samples ELISA Kit for Hyaluronic Acid (HA) Results demonstration
  • MEA182Ge.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Mini Samples ELISA Kit for Hyaluronic Acid (HA)

This assay has high sensitivity and excellent specificity for detection of Mini Samples Hyaluronic Acid (HA).
No significant cross-reactivity or interference between Mini Samples Hyaluronic Acid (HA) and analogues was observed.

Recovery of the Mini Samples ELISA Kit for Hyaluronic Acid (HA)

Matrices listed below were spiked with certain level of Mini Samples Hyaluronic Acid (HA) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Hyaluronic Acid (HA) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-103 97
EDTA plasma(n=5) 78-89 84
heparin plasma(n=5) 80-97 80

Precision of the Mini Samples ELISA Kit for Hyaluronic Acid (HA)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Hyaluronic Acid (HA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Hyaluronic Acid (HA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Mini Samples ELISA Kit for Hyaluronic Acid (HA)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Hyaluronic Acid (HA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 96-104% 80-92% 83-92% 79-98%
EDTA plasma(n=5) 98-105% 90-101% 97-105% 80-94%
heparin plasma(n=5) 82-93% 78-94% 90-104% 80-93%

Stability of the Mini Samples ELISA Kit for Hyaluronic Acid (HA)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Mini Samples ELISA Kit for Hyaluronic Acid (HA)

1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well.
    And then add 25μL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 50µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 50µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 25µL Stop Solution. Read at 450 nm immediately.

Test principle of the Mini Samples ELISA Kit for Hyaluronic Acid (HA)

This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Mini Samples Hyaluronic Acid (HA) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Mini Samples Hyaluronic Acid (HA) and unlabeled Mini Samples Hyaluronic Acid (HA) (Standards or samples) with the pre-coated antibody specific to Mini Samples Hyaluronic Acid (HA). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Mini Samples Hyaluronic Acid (HA) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Mini Samples Hyaluronic Acid (HA) in the sample.

Related products

Catalog No. Organism species: Pan-species (General) Applications (RESEARCH USE ONLY!)
CPA182Ge11 BSA Conjugated Hyaluronic Acid (HA) Immunogen; SDS-PAGE; WB.
CPA182Ge21 OVA Conjugated Hyaluronic Acid (HA) Immunogen; SDS-PAGE; WB.
PAA182Ge01 Polyclonal Antibody to Hyaluronic Acid (HA) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
PAA182Ge02 Polyclonal Antibody to Hyaluronic Acid (HA) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
LAA182Ge81 FITC-Linked Polyclonal Antibody to Hyaluronic Acid (HA) WB; IHC; ICC; IF.
LAA182Ge71 Biotin-Linked Polyclonal Antibody to Hyaluronic Acid (HA) WB; IHC; ICC.
MAA182Ge22 Monoclonal Antibody to Hyaluronic Acid (HA) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA182Ge21 Monoclonal Antibody to Hyaluronic Acid (HA) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MEA182Ge Mini Samples ELISA Kit for Hyaluronic Acid (HA) Enzyme-linked immunosorbent assay for Antigen Detection.
CEA182Ge ELISA Kit for Hyaluronic Acid (HA) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA182Ge Multiplex Assay Kit for Hyaluronic Acid (HA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA182Ge11 ELISA Kit DIY Materials for Hyaluronic Acid (HA) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK