Mini Samples ELISA Kit for Glucuronidase Beta (GUSb)

GUS-B; MPS7; Beta-G1

  • Mini Samples ELISA Kit for Glucuronidase Beta (GUSb) Packages (Simulation)
  • Mini Samples ELISA Kit for Glucuronidase Beta (GUSb) Packages (Simulation)
  • Mini Samples ELISA Kit for Glucuronidase Beta (GUSb) Results demonstration
  • MEB416Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Mini Samples ELISA Kit for Glucuronidase Beta (GUSb)

This assay has high sensitivity and excellent specificity for detection of Mini Samples Glucuronidase Beta (GUSb).
No significant cross-reactivity or interference between Mini Samples Glucuronidase Beta (GUSb) and analogues was observed.

Recovery of the Mini Samples ELISA Kit for Glucuronidase Beta (GUSb)

Matrices listed below were spiked with certain level of recombinant Mini Samples Glucuronidase Beta (GUSb) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Glucuronidase Beta (GUSb) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-102 99
EDTA plasma(n=5) 80-105 99
heparin plasma(n=5) 84-101 88

Precision of the Mini Samples ELISA Kit for Glucuronidase Beta (GUSb)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Glucuronidase Beta (GUSb) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Glucuronidase Beta (GUSb) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Mini Samples ELISA Kit for Glucuronidase Beta (GUSb)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Glucuronidase Beta (GUSb) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-101% 94-102% 85-99% 81-99%
EDTA plasma(n=5) 96-104% 83-90% 84-104% 94-101%
heparin plasma(n=5) 78-95% 80-102% 89-97% 94-103%

Stability of the Mini Samples ELISA Kit for Glucuronidase Beta (GUSb)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Mini Samples ELISA Kit for Glucuronidase Beta (GUSb)

1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.

Test principle of the Mini Samples ELISA Kit for Glucuronidase Beta (GUSb)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mini Samples Glucuronidase Beta (GUSb). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Mini Samples Glucuronidase Beta (GUSb). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mini Samples Glucuronidase Beta (GUSb), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mini Samples Glucuronidase Beta (GUSb) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPB416Hu01 Recombinant Glucuronidase Beta (GUSb) Positive Control; Immunogen; SDS-PAGE; WB.
PAB416Hu01 Polyclonal Antibody to Glucuronidase Beta (GUSb) WB,IHC,ICC/IF
LAB416Hu71 Biotin-Linked Polyclonal Antibody to Glucuronidase Beta (GUSb) WB; IHC; ICC.
MAB416Hu22 Monoclonal Antibody to Glucuronidase Beta (GUSb) WB; IHC; ICC; IP.
MEB416Hu Mini Samples ELISA Kit for Glucuronidase Beta (GUSb) Enzyme-linked immunosorbent assay for Antigen Detection.
SEB416Hu ELISA Kit for Glucuronidase Beta (GUSb) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB416Hu Multiplex Assay Kit for Glucuronidase Beta (GUSb) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK