Mini Samples ELISA Kit for Complement 1 Inhibitor (C1INH)

SERPING1; C1IN; C1-INH; C1NH; HAE1; HAE2; Serpin Peptidase Inhibitor Clade G Member 1; Angioedema Hereditary; C1 Inhibitor; C1 Esterase Inhibitor

  • Mini Samples ELISA Kit for Complement 1 Inhibitor (C1INH) Packages (Simulation)
  • Mini Samples ELISA Kit for Complement 1 Inhibitor (C1INH) Packages (Simulation)
  • Mini Samples ELISA Kit for Complement 1 Inhibitor (C1INH) Results demonstration
  • MEA235Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Mini Samples ELISA Kit for Complement 1 Inhibitor (C1INH)

This assay has high sensitivity and excellent specificity for detection of Mini Samples Complement 1 Inhibitor (C1INH).
No significant cross-reactivity or interference between Mini Samples Complement 1 Inhibitor (C1INH) and analogues was observed.

Recovery of the Mini Samples ELISA Kit for Complement 1 Inhibitor (C1INH)

Matrices listed below were spiked with certain level of recombinant Mini Samples Complement 1 Inhibitor (C1INH) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Complement 1 Inhibitor (C1INH) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 102
EDTA plasma(n=5) 95-104 99
heparin plasma(n=5) 80-97 93

Precision of the Mini Samples ELISA Kit for Complement 1 Inhibitor (C1INH)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Complement 1 Inhibitor (C1INH) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Complement 1 Inhibitor (C1INH) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Mini Samples ELISA Kit for Complement 1 Inhibitor (C1INH)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Complement 1 Inhibitor (C1INH) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-99% 90-97% 87-101% 78-95%
EDTA plasma(n=5) 94-101% 84-103% 85-93% 85-99%
heparin plasma(n=5) 96-105% 84-97% 94-104% 83-91%

Stability of the Mini Samples ELISA Kit for Complement 1 Inhibitor (C1INH)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Mini Samples ELISA Kit for Complement 1 Inhibitor (C1INH)

1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.

Test principle of the Mini Samples ELISA Kit for Complement 1 Inhibitor (C1INH)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mini Samples Complement 1 Inhibitor (C1INH). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Mini Samples Complement 1 Inhibitor (C1INH). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mini Samples Complement 1 Inhibitor (C1INH), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mini Samples Complement 1 Inhibitor (C1INH) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA235Mu01 Recombinant Complement 1 Inhibitor (C1INH) Positive Control; Immunogen; SDS-PAGE; WB.
RPA235Mu02 Recombinant Complement 1 Inhibitor (C1INH) Positive Control; Immunogen; SDS-PAGE; WB.
RPA235Mu03 Recombinant Complement 1 Inhibitor (C1INH) Positive Control; Immunogen; SDS-PAGE; WB.
RPA235Mu04 Recombinant Complement 1 Inhibitor (C1INH) Positive Control; Immunogen; SDS-PAGE; WB.
RPA235Mu05 Recombinant Complement 1 Inhibitor (C1INH) Positive Control; Immunogen; SDS-PAGE; WB.
RPA235Mu06 Recombinant Complement 1 Inhibitor (C1INH) Positive Control; Immunogen; SDS-PAGE; WB.
RPA235Mu07 Recombinant Complement 1 Inhibitor (C1INH) Positive Control; Immunogen; SDS-PAGE; WB.
RPA235Mu08 Recombinant Complement 1 Inhibitor (C1INH) Positive Control; Immunogen; SDS-PAGE; WB.
PAA235Mu01 Polyclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC; IP.
PAA235Mu04 Polyclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC; IP.
PAA235Mu05 Polyclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC; IP.
PAA235Mu03 Polyclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC; IP.
PAA235Mu02 Polyclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC; IP.
LAA235Mu71 Biotin-Linked Polyclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC.
LAA235Mu81 FITC-Linked Polyclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC; IF.
SEA235Mu ELISA Kit for Complement 1 Inhibitor (C1INH) Enzyme-linked immunosorbent assay for Antigen Detection.
MEA235Mu Mini Samples ELISA Kit for Complement 1 Inhibitor (C1INH) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA235Mu Multiplex Assay Kit for Complement 1 Inhibitor (C1INH) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.