Mini Samples ELISA Kit for Atrial Natriuretic Peptide (ANP)

ANH; ANF; CDD; Atrial Natriuretic Factor; Atrial Natriuretic Hormone; Atriopeptin; Cardionatrine; Cardiodilatin

  • Mini Samples ELISA Kit for Atrial Natriuretic Peptide (ANP) Packages (Simulation)
  • Mini Samples ELISA Kit for Atrial Natriuretic Peptide (ANP) Packages (Simulation)
  • Mini Samples ELISA Kit for Atrial Natriuretic Peptide (ANP) Results demonstration
  • MEA225Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Mini Samples ELISA Kit for Atrial Natriuretic Peptide (ANP)

This assay has high sensitivity and excellent specificity for detection of Mini Samples Atrial Natriuretic Peptide (ANP).
No significant cross-reactivity or interference between Mini Samples Atrial Natriuretic Peptide (ANP) and analogues was observed.

Recovery of the Mini Samples ELISA Kit for Atrial Natriuretic Peptide (ANP)

Matrices listed below were spiked with certain level of recombinant Mini Samples Atrial Natriuretic Peptide (ANP) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Atrial Natriuretic Peptide (ANP) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 82-92 85
EDTA plasma(n=5) 95-104 101
heparin plasma(n=5) 97-105 101

Precision of the Mini Samples ELISA Kit for Atrial Natriuretic Peptide (ANP)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Atrial Natriuretic Peptide (ANP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Atrial Natriuretic Peptide (ANP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Mini Samples ELISA Kit for Atrial Natriuretic Peptide (ANP)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Atrial Natriuretic Peptide (ANP) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-98% 89-98% 80-89% 96-105%
EDTA plasma(n=5) 83-91% 90-103% 98-105% 92-101%
heparin plasma(n=5) 84-93% 78-103% 86-101% 95-102%

Stability of the Mini Samples ELISA Kit for Atrial Natriuretic Peptide (ANP)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Mini Samples ELISA Kit for Atrial Natriuretic Peptide (ANP)

1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.

Test principle of the Mini Samples ELISA Kit for Atrial Natriuretic Peptide (ANP)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mini Samples Atrial Natriuretic Peptide (ANP). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Mini Samples Atrial Natriuretic Peptide (ANP). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mini Samples Atrial Natriuretic Peptide (ANP), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mini Samples Atrial Natriuretic Peptide (ANP) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA225Mu02 Recombinant Atrial Natriuretic Peptide (ANP) Positive Control; Immunogen; SDS-PAGE; WB.
RPA225Mu01 Recombinant Atrial Natriuretic Peptide (ANP) Positive Control; Immunogen; SDS-PAGE; WB.
PAA225Mu02 Polyclonal Antibody to Atrial Natriuretic Peptide (ANP) WB; IHC; ICC; IP.
PAA225Mu01 Polyclonal Antibody to Atrial Natriuretic Peptide (ANP) WB; IHC; ICC; IP.
LAA225Mu71 Biotin-Linked Polyclonal Antibody to Atrial Natriuretic Peptide (ANP) WB; IHC; ICC.
SEA225Mu ELISA Kit for Atrial Natriuretic Peptide (ANP) Enzyme-linked immunosorbent assay for Antigen Detection.
MEA225Mu Mini Samples ELISA Kit for Atrial Natriuretic Peptide (ANP) Enzyme-linked immunosorbent assay for Antigen Detection.
CEA225Mu ELISA Kit for Atrial Natriuretic Peptide (ANP) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA225Mu Multiplex Assay Kit for Atrial Natriuretic Peptide (ANP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA225Mu11 ELISA Kit DIY Materials for Atrial Natriuretic Peptide (ANP) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK