Multiplex Assay Kit for Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Pantetheinase; Pantetheine hydrolase; Tiff66; Vascular non-inflammatory molecule 1

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-101 96
EDTA plasma(n=5) 85-96 90
heparin plasma(n=5) 95-103 101

Precision of the Multiplex Assay Kit for Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-103% 92-105% 81-101% 94-102%
EDTA plasma(n=5) 96-104% 84-103% 80-90% 86-94%
heparin plasma(n=5) 83-105% 78-92% 87-101% 83-93%

Stability of the Multiplex Assay Kit for Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPC598Hu02 Recombinant Vanin 1 (VNN1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC598Hu03 Recombinant Vanin 1 (VNN1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC598Hu01 Recombinant Vanin 1 (VNN1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC598Hu05 Recombinant Vanin 1 (VNN1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC598Hu04 Recombinant Vanin 1 (VNN1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC598Hu02 Polyclonal Antibody to Vanin 1 (VNN1) WB; IHC; ICC; IP.
PAC598Hu04 Polyclonal Antibody to Vanin 1 (VNN1) WB; IHC; ICC; IP.
PAC598Hu03 Polyclonal Antibody to Vanin 1 (VNN1) WB
PAC598Hu01 Polyclonal Antibody to Vanin 1 (VNN1) WB; IHC; ICC; IP.
LAC598Hu71 Biotin-Linked Polyclonal Antibody to Vanin 1 (VNN1) WB; IHC; ICC.
MAC598Hu24 Monoclonal Antibody to Vanin 1 (VNN1) WB
MAC598Hu21 Monoclonal Antibody to Vanin 1 (VNN1) WB
MAC598Hu22 Monoclonal Antibody to Vanin 1 (VNN1) WB; IHC; ICC; IP.
SEC598Hu ELISA Kit for Vanin 1 (VNN1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC598Hu Multiplex Assay Kit for Vanin 1 (VNN1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSC598Hu01 ELISA Kit DIY Materials for Vanin 1 (VNN1) Main materials for "Do It(ELISA Kit) Yourself"
GUESTBOOK