Multiplex Assay Kit for C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay)

C-RP; PTX1; Pentraxin-Related; Pentraxin 1

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 96-105 102
heparin plasma(n=5) 91-103 98

Precision of the Multiplex Assay Kit for C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-101% 86-94% 83-101% 87-98%
EDTA plasma(n=5) 87-94% 80-93% 86-95% 84-94%
heparin plasma(n=5) 78-104% 87-105% 83-96% 86-96%

Stability of the Multiplex Assay Kit for C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APA821Hu01 Active C Reactive Protein (CRP) Cell culture; Activity Assays.
NPA821Hu02 Native C Reactive Protein (CRP) Positive Control; Immunogen; SDS-PAGE; WB.
NPA821Hu01 Native C Reactive Protein (CRP) Positive Control; Immunogen; SDS-PAGE; WB.
RPA821Hu01 Recombinant C Reactive Protein (CRP) Positive Control; Immunogen; SDS-PAGE; WB.
APA821Hu02 Active C Reactive Protein (CRP) Cell culture; Activity Assays.
APA821Hu61 Active C Reactive Protein (CRP) Cell culture; Activity Assays.
PAA821Hu02 Polyclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
PAA821Hu01 Polyclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
LAA821Hu71 Biotin-Linked Polyclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC.
RAA821Hu22 Recombinant Antibody to C Reactive Protein (CRP) WB; IHC; ICC.
RAA821Hu23 Recombinant Antibody to C Reactive Protein (CRP) WB; IHC; ICC.
MAA821Hu29 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
MAA821Hu21 Monoclonal Antibody to C Reactive Protein (CRP) WB
MAA821Hu26 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
MAA821Hu27 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
MAA821Hu28 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
MAA821Hu24 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
MAA821Hu25 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
RAA821Hu25 Recombinant Antibody to C Reactive Protein (CRP) WB; IF; ICC; IHC; IP; FCM.
RAA821Hu21 Recombinant Antibody to C Reactive Protein (CRP) WB; IHC; ICC.
MAA821Hu23 Monoclonal Antibody to C Reactive Protein (CRP) WB
MAA821Hu22 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC
FAA821Hu08 Anti-C Reactive Protein (CRP) Monoclonal Antibody Flow cytometry.
FAA821Hu02 Anti-C Reactive Protein (CRP) Monoclonal Antibody Flow cytometry.
FAA821Hu06 Anti-C Reactive Protein (CRP) Monoclonal Antibody Flow cytometry.
FAA821Hu04 Anti-C Reactive Protein (CRP) Monoclonal Antibody Flow cytometry.
LAA821Hu72 Biotin-Linked Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC.
HEA821Hu High Sensitive ELISA Kit for C Reactive Protein (CRP) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA821Hu ELISA Kit for C Reactive Protein (CRP) Enzyme-linked immunosorbent assay for Antigen Detection.
AEA821Hu ELISA Kit for Anti-C Reactive Protein Antibody (Anti-CRP) Enzyme-linked immunosorbent assay for Antibody Detection.
SCA821Hu CLIA Kit for C Reactive Protein (CRP) Chemiluminescent immunoassay for Antigen Detection.
LMA821Hu Multiplex Assay Kit for C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSA821Hu01 Antibody Pair for C Reactive Protein (CRP) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
KSA821Hu01 ELISA Kit DIY Materials for C Reactive Protein (CRP) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK