Instant ELISA Kit for Epinephrine (EPI)

Adrenaline

  • Instant ELISA Kit for Epinephrine (EPI) Packages (Simulation)
  • Instant ELISA Kit for Epinephrine (EPI) Packages (Simulation)
  • Instant ELISA Kit for Epinephrine (EPI) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Instant ELISA Kit for Epinephrine (EPI)

This assay has high sensitivity and excellent specificity for detection of Instant Epinephrine (EPI).
No significant cross-reactivity or interference between Instant Epinephrine (EPI) and analogues was observed.

Recovery of the Instant ELISA Kit for Epinephrine (EPI)

Matrices listed below were spiked with certain level of Instant Epinephrine (EPI) and the recovery rates were calculated by comparing the measured value to the expected amount of Instant Epinephrine (EPI) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-97 93
EDTA plasma(n=5) 84-93 89
heparin plasma(n=5) 87-101 96

Precision of the Instant ELISA Kit for Epinephrine (EPI)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Instant Epinephrine (EPI) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Instant Epinephrine (EPI) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Instant ELISA Kit for Epinephrine (EPI)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Instant Epinephrine (EPI) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-101% 80-95% 84-104% 87-94%
EDTA plasma(n=5) 78-103% 79-90% 93-101% 79-95%
heparin plasma(n=5) 99-105% 78-98% 86-94% 99-105%

Stability of the Instant ELISA Kit for Epinephrine (EPI)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Instant ELISA Kit for Epinephrine (EPI)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 30 minutes at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 30 minutes at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 10 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the Instant ELISA Kit for Epinephrine (EPI)

The test principle applied in this kit is enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Instant Epinephrine (EPI). Standards or samples and HRP-labeled detection antibody specific to Instant Epinephrine (EPI) (Detection Reagent A) are then added to the appropriate microtiter plate wells. Next, TMB substrate solution is added, only those wells that contain Instant Epinephrine (EPI), and HRP-labeled detection antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Instant Epinephrine (EPI) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Pan-species (General) Applications (RESEARCH USE ONLY!)
CPA858Ge11 BSA Conjugated Epinephrine (EPI) Immunogen; SDS-PAGE; WB.
CPA858Ge21 OVA Conjugated Epinephrine (EPI) Immunogen; SDS-PAGE; WB.
PAA858Ge01 Polyclonal Antibody to Epinephrine (EPI) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA858Ge26 Monoclonal Antibody to Epinephrine (EPI) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA858Ge25 Monoclonal Antibody to Epinephrine (EPI) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA858Ge22 Monoclonal Antibody to Epinephrine (EPI) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
CEA858Ge ELISA Kit for Epinephrine (EPI) Enzyme-linked immunosorbent assay for Antigen Detection.
IEA858Ge Instant ELISA Kit for Epinephrine (EPI) Enzyme-linked immunosorbent assay for Antigen Detection.
HEA858Ge High Sensitive ELISA Kit for Epinephrine (EPI) Enzyme-linked immunosorbent assay for Antigen Detection.
MEA858Ge Mini Samples ELISA Kit for Epinephrine (EPI) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA858Ge Multiplex Assay Kit for Epinephrine (EPI) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA858Ge11 ELISA Kit DIY Materials for Epinephrine (EPI) Main materials for "Do It (ELISA Kit) Yourself".