High Sensitive ELISA Kit for Interleukin 28B (IL28B)

IFNL3; Interferon,Lambda 3; Cytokine Zcyto22

  • High Sensitive ELISA Kit for Interleukin 28B (IL28B) Packages (Simulation)
  • High Sensitive ELISA Kit for Interleukin 28B (IL28B) Packages (Simulation)
  • High Sensitive ELISA Kit for Interleukin 28B (IL28B) Results demonstration
  • HEC028Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)

This assay has high sensitivity and excellent specificity for detection of High Sensitive Interleukin 28B (IL28B).
No significant cross-reactivity or interference between High Sensitive Interleukin 28B (IL28B) and analogues was observed.

Recovery of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)

Matrices listed below were spiked with certain level of recombinant High Sensitive Interleukin 28B (IL28B) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive Interleukin 28B (IL28B) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-101 95
EDTA plasma(n=5) 83-95 91
heparin plasma(n=5) 80-95 79

Precision of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Interleukin 28B (IL28B) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Interleukin 28B (IL28B) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive Interleukin 28B (IL28B) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 96-104% 89-104% 99-105%
EDTA plasma(n=5) 86-98% 91-99% 80-91% 78-105%
heparin plasma(n=5) 96-104% 92-99% 84-105% 93-103%

Stability of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Interleukin 28B (IL28B). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Interleukin 28B (IL28B). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Interleukin 28B (IL28B), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Sensitive Interleukin 28B (IL28B) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APC028Hu01 Active Interleukin 28B (IL28B) Cell culture; Activity Assays.
RPC028Hu01 Recombinant Interleukin 28B (IL28B) Positive Control; Immunogen; SDS-PAGE; WB.
PAC028Hu01 Polyclonal Antibody to Interleukin 28B (IL28B) WB; IHC; ICC; IP.
LAC028Hu81 FITC-Linked Polyclonal Antibody to Interleukin 28B (IL28B) WB; IHC; ICC; IF.
LAC028Hu71 Biotin-Linked Polyclonal Antibody to Interleukin 28B (IL28B) WB; IHC; ICC.
MAC028Hu22 Monoclonal Antibody to Interleukin 28B (IL28B) WB; IHC; ICC; IP.
HEC028Hu High Sensitive ELISA Kit for Interleukin 28B (IL28B) Enzyme-linked immunosorbent assay for Antigen Detection.
SEC028Hu ELISA Kit for Interleukin 28B (IL28B) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC028Hu CLIA Kit for Interleukin 28B (IL28B) Chemiluminescent immunoassay for Antigen Detection.
LMC028Hu Multiplex Assay Kit for Interleukin 28B (IL28B) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK