High Sensitive ELISA Kit for Inhibin Beta E (INHbE)

INH-bE; Activin beta-E chain

  • High Sensitive ELISA Kit for Inhibin Beta E (INHbE) Packages (Simulation)
  • High Sensitive ELISA Kit for Inhibin Beta E (INHbE) Packages (Simulation)
  • High Sensitive ELISA Kit for Inhibin Beta E (INHbE) Results demonstration
  • HEA048Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the High Sensitive ELISA Kit for Inhibin Beta E (INHbE)

This assay has high sensitivity and excellent specificity for detection of High Sensitive Inhibin Beta E (INHbE).
No significant cross-reactivity or interference between High Sensitive Inhibin Beta E (INHbE) and analogues was observed.

Recovery of the High Sensitive ELISA Kit for Inhibin Beta E (INHbE)

Matrices listed below were spiked with certain level of recombinant High Sensitive Inhibin Beta E (INHbE) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive Inhibin Beta E (INHbE) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-103 98
EDTA plasma(n=5) 78-95 89
heparin plasma(n=5) 89-96 92

Precision of the High Sensitive ELISA Kit for Inhibin Beta E (INHbE)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Inhibin Beta E (INHbE) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Inhibin Beta E (INHbE) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the High Sensitive ELISA Kit for Inhibin Beta E (INHbE)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive Inhibin Beta E (INHbE) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-96% 94-101% 93-103% 78-98%
EDTA plasma(n=5) 82-92% 92-101% 80-101% 78-102%
heparin plasma(n=5) 93-101% 87-101% 82-104% 98-105%

Stability of the High Sensitive ELISA Kit for Inhibin Beta E (INHbE)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the High Sensitive ELISA Kit for Inhibin Beta E (INHbE)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the High Sensitive ELISA Kit for Inhibin Beta E (INHbE)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Inhibin Beta E (INHbE). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Inhibin Beta E (INHbE). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Inhibin Beta E (INHbE), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Sensitive Inhibin Beta E (INHbE) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA048Mu01 Recombinant Inhibin Beta E (INHbE) Positive Control; Immunogen; SDS-PAGE; WB.
RPA048Mu02 Recombinant Inhibin Beta E (INHbE) Positive Control; Immunogen; SDS-PAGE; WB.
PAA048Mu01 Polyclonal Antibody to Inhibin Beta E (INHbE) WB,IHC
PAA048Mu02 Polyclonal Antibody to Inhibin Beta E (INHbE) WB; IHC; ICC; IP.
SEA048Mu ELISA Kit for Inhibin Beta E (INHbE) Enzyme-linked immunosorbent assay for Antigen Detection.
HEA048Mu High Sensitive ELISA Kit for Inhibin Beta E (INHbE) Enzyme-linked immunosorbent assay for Antigen Detection.
CEA048Mu ELISA Kit for Inhibin Beta E (INHbE) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA048Mu Multiplex Assay Kit for Inhibin Beta E (INHbE) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK