High Sensitive ELISA Kit for Cathepsin D (CTSD)

CPSD; CLN10; Lysosomal Aspartyl Protease; Ceroid-Lipofuscinosis,Neuronal 10

  • High Sensitive ELISA Kit for Cathepsin D (CTSD) Packages (Simulation)
  • High Sensitive ELISA Kit for Cathepsin D (CTSD) Packages (Simulation)
  • High Sensitive ELISA Kit for Cathepsin D (CTSD) Results demonstration
  • HEB280Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the High Sensitive ELISA Kit for Cathepsin D (CTSD)

This assay has high sensitivity and excellent specificity for detection of High Sensitive Cathepsin D (CTSD).
No significant cross-reactivity or interference between High Sensitive Cathepsin D (CTSD) and analogues was observed.

Recovery of the High Sensitive ELISA Kit for Cathepsin D (CTSD)

Matrices listed below were spiked with certain level of recombinant High Sensitive Cathepsin D (CTSD) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive Cathepsin D (CTSD) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-98 94
EDTA plasma(n=5) 85-105 93
heparin plasma(n=5) 82-101 89

Precision of the High Sensitive ELISA Kit for Cathepsin D (CTSD)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Cathepsin D (CTSD) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Cathepsin D (CTSD) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the High Sensitive ELISA Kit for Cathepsin D (CTSD)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive Cathepsin D (CTSD) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-102% 78-104% 78-101% 81-97%
EDTA plasma(n=5) 89-98% 91-101% 80-92% 81-94%
heparin plasma(n=5) 91-105% 92-105% 79-102% 82-92%

Stability of the High Sensitive ELISA Kit for Cathepsin D (CTSD)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the High Sensitive ELISA Kit for Cathepsin D (CTSD)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the High Sensitive ELISA Kit for Cathepsin D (CTSD)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Cathepsin D (CTSD). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Cathepsin D (CTSD). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Cathepsin D (CTSD), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Sensitive Cathepsin D (CTSD) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APB280Hu61 Active Cathepsin D (CTSD) Cell culture; Activity Assays.
EPB280Hu61 Eukaryotic Cathepsin D (CTSD) Positive Control; Immunogen; SDS-PAGE; WB.
RPB280Hu01 Recombinant Cathepsin D (CTSD) Positive Control; Immunogen; SDS-PAGE; WB.
EPB280Hu62 Eukaryotic Cathepsin D (CTSD) Positive Control; Immunogen; SDS-PAGE; WB.
RPB280Hu02 Recombinant Cathepsin D (CTSD) Positive Control; Immunogen; SDS-PAGE; WB.
RPB280Hu03 Recombinant Cathepsin D (CTSD) Positive Control; Immunogen; SDS-PAGE; WB.
RPB280Hu04 Recombinant Cathepsin D (CTSD) Positive Control; Immunogen; SDS-PAGE; WB.
PAB280Hu02 Polyclonal Antibody to Cathepsin D (CTSD) WB; IHC; ICC; IP.
PAB280Hu01 Polyclonal Antibody to Cathepsin D (CTSD) WB; IHC; ICC; IP.
LAB280Hu71 Biotin-Linked Polyclonal Antibody to Cathepsin D (CTSD) WB; IHC; ICC.
MAB280Hu21 Monoclonal Antibody to Cathepsin D (CTSD) WB; IHC; ICC; IP.
MAB280Hu26 Monoclonal Antibody to Cathepsin D (CTSD) WB; IHC; ICC; IP.
MAB280Hu22 Monoclonal Antibody to Cathepsin D (CTSD) WB; IHC; ICC; IP.
FAB280Hu02 Anti-Cathepsin D (CTSD) Monoclonal Antibody Flow cytometry.
SEB280Hu ELISA Kit for Cathepsin D (CTSD) Enzyme-linked immunosorbent assay for Antigen Detection.
HEB280Hu High Sensitive ELISA Kit for Cathepsin D (CTSD) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB280Hu Multiplex Assay Kit for Cathepsin D (CTSD) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK