High Sensitive ELISA Kit for C Reactive Protein (CRP)

C-RP; PTX1; Pentraxin-Related; Pentraxin 1

  • High Sensitive ELISA Kit for C Reactive Protein (CRP) Packages (Simulation)
  • High Sensitive ELISA Kit for C Reactive Protein (CRP) Packages (Simulation)
  • High Sensitive ELISA Kit for C Reactive Protein (CRP) Results demonstration
  • HEA821Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the High Sensitive ELISA Kit for C Reactive Protein (CRP)

This assay has high sensitivity and excellent specificity for detection of High Sensitive C Reactive Protein (CRP).
No significant cross-reactivity or interference between High Sensitive C Reactive Protein (CRP) and analogues was observed.

Recovery of the High Sensitive ELISA Kit for C Reactive Protein (CRP)

Matrices listed below were spiked with certain level of recombinant High Sensitive C Reactive Protein (CRP) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive C Reactive Protein (CRP) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-92 88
EDTA plasma(n=5) 84-101 88
heparin plasma(n=5) 79-96 83

Precision of the High Sensitive ELISA Kit for C Reactive Protein (CRP)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive C Reactive Protein (CRP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive C Reactive Protein (CRP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the High Sensitive ELISA Kit for C Reactive Protein (CRP)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive C Reactive Protein (CRP) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 96-105% 81-93% 85-99% 86-101%
EDTA plasma(n=5) 84-92% 78-103% 97-104% 93-105%
heparin plasma(n=5) 92-99% 91-98% 79-90% 86-104%

Stability of the High Sensitive ELISA Kit for C Reactive Protein (CRP)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the High Sensitive ELISA Kit for C Reactive Protein (CRP)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the High Sensitive ELISA Kit for C Reactive Protein (CRP)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive C Reactive Protein (CRP). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive C Reactive Protein (CRP). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive C Reactive Protein (CRP), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Sensitive C Reactive Protein (CRP) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APA821Hu01 Active C Reactive Protein (CRP) Cell culture; Activity Assays.
NPA821Hu02 Native C Reactive Protein (CRP) Positive Control; Immunogen; SDS-PAGE; WB.
NPA821Hu01 Native C Reactive Protein (CRP) Positive Control; Immunogen; SDS-PAGE; WB.
RPA821Hu01 Recombinant C Reactive Protein (CRP) Positive Control; Immunogen; SDS-PAGE; WB.
APA821Hu02 Active C Reactive Protein (CRP) Cell culture; Activity Assays.
APA821Hu61 Active C Reactive Protein (CRP) Cell culture; Activity Assays.
PAA821Hu02 Polyclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
PAA821Hu01 Polyclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
LAA821Hu71 Biotin-Linked Polyclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC.
RAA821Hu22 Recombinant Antibody to C Reactive Protein (CRP) WB; IHC; ICC.
RAA821Hu23 Recombinant Antibody to C Reactive Protein (CRP) WB; IHC; ICC.
MAA821Hu29 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
MAA821Hu21 Monoclonal Antibody to C Reactive Protein (CRP) WB
MAA821Hu26 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
MAA821Hu27 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
MAA821Hu28 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
MAA821Hu24 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
MAA821Hu25 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC; IP.
RAA821Hu25 Recombinant Antibody to C Reactive Protein (CRP) WB; IF; ICC; IHC; IP; FCM.
RAA821Hu21 Recombinant Antibody to C Reactive Protein (CRP) WB; IHC; ICC.
MAA821Hu23 Monoclonal Antibody to C Reactive Protein (CRP) WB
MAA821Hu22 Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC
FAA821Hu08 Anti-C Reactive Protein (CRP) Monoclonal Antibody Flow cytometry.
FAA821Hu02 Anti-C Reactive Protein (CRP) Monoclonal Antibody Flow cytometry.
FAA821Hu06 Anti-C Reactive Protein (CRP) Monoclonal Antibody Flow cytometry.
FAA821Hu04 Anti-C Reactive Protein (CRP) Monoclonal Antibody Flow cytometry.
LAA821Hu72 Biotin-Linked Monoclonal Antibody to C Reactive Protein (CRP) WB; IHC; ICC.
HEA821Hu High Sensitive ELISA Kit for C Reactive Protein (CRP) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA821Hu ELISA Kit for C Reactive Protein (CRP) Enzyme-linked immunosorbent assay for Antigen Detection.
AEA821Hu ELISA Kit for Anti-C Reactive Protein Antibody (Anti-CRP) Enzyme-linked immunosorbent assay for Antibody Detection.
SCA821Hu CLIA Kit for C Reactive Protein (CRP) Chemiluminescent immunoassay for Antigen Detection.
LMA821Hu Multiplex Assay Kit for C Reactive Protein (CRP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSA821Hu01 Antibody Pair for C Reactive Protein (CRP) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
KSA821Hu01 ELISA Kit DIY Materials for C Reactive Protein (CRP) Main materials for "Do It (ELISA Kit) Yourself".