ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

NTN; ABCD3; C3Xkine; CXC3; CXC3C; NTT; SCYD1; ABCD3; FKN; Neurotactin; Fractalkine; Small Inducible Cytokine Subfamily D(Cys-X3-Cys)Member 1

  • ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Packages (Simulation)
  • ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Packages (Simulation)
  • ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Results demonstration
  • SEA040Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

This assay has high sensitivity and excellent specificity for detection of Chemokine C-X3-C-Motif Ligand 1 (CX3CL1).
No significant cross-reactivity or interference between Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) and analogues was observed.

Recovery of the ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

Matrices listed below were spiked with certain level of recombinant Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) and the recovery rates were calculated by comparing the measured value to the expected amount of Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-104 99
EDTA plasma(n=5) 78-89 82
heparin plasma(n=5) 97-105 102

Precision of the ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-104% 85-93% 99-105% 82-99%
EDTA plasma(n=5) 96-104% 97-105% 88-97% 84-95%
heparin plasma(n=5) 94-104% 93-103% 89-103% 91-98%

Stability of the ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Chemokine C-X3-C-Motif Ligand 1 (CX3CL1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
APA040Ra01 Active Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Cell culture; Activity Assays.
RPA040Ra01 Recombinant Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA040Ra01 Polyclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) WB; IHC; ICC; IP.
LAA040Ra81 FITC-Linked Polyclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) WB; IHC; ICC; IF.
LAA040Ra71 Biotin-Linked Polyclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) WB; IHC; ICC.
MAA040Ra21 Monoclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) WB; IHC; ICC; IP.
SEA040Ra ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA040Ra CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Chemiluminescent immunoassay for Antigen Detection.
LMA040Ra Multiplex Assay Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK