ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

OL

  • ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL) Packages (Simulation)
  • ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL) Packages (Simulation)
  • ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL) Results demonstration
  • SEA527Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

This assay has high sensitivity and excellent specificity for detection of Oxidized Low Density Lipoprotein (OxLDL).
No significant cross-reactivity or interference between Oxidized Low Density Lipoprotein (OxLDL) and analogues was observed.

Recovery of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

Matrices listed below were spiked with certain level of recombinant Oxidized Low Density Lipoprotein (OxLDL) and the recovery rates were calculated by comparing the measured value to the expected amount of Oxidized Low Density Lipoprotein (OxLDL) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-101 94
EDTA plasma(n=5) 80-91 87
heparin plasma(n=5) 91-99 95

Precision of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Oxidized Low Density Lipoprotein (OxLDL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Oxidized Low Density Lipoprotein (OxLDL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Oxidized Low Density Lipoprotein (OxLDL) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-101% 81-93% 80-94% 94-102%
EDTA plasma(n=5) 93-101% 79-90% 80-101% 92-99%
heparin plasma(n=5) 98-105% 87-104% 88-102% 85-95%

Stability of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Oxidized Low Density Lipoprotein (OxLDL). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Oxidized Low Density Lipoprotein (OxLDL). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Oxidized Low Density Lipoprotein (OxLDL), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Oxidized Low Density Lipoprotein (OxLDL) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
SPA527Hu01 Synthetic Oxidized Low Density Lipoprotein (OxLDL) Immunogen; Blocking Peptide.
PAA527Hu08 Polyclonal Antibody to Oxidized Low Density Lipoprotein (OxLDL) IHC; ICC; IP
SEA527Hu ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL) Enzyme-linked immunosorbent assay for Antigen Detection.
CEA527Hu ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA527Hu Multiplex Assay Kit for Oxidized Low Density Lipoprotein (OxLDL) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSA527Hu11 Antibody Pair for Oxidized Low Density Lipoprotein (OxLDL) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
KSA527Hu11 ELISA Kit DIY Materials for Oxidized Low Density Lipoprotein (OxLDL) Main materials for "Do It (ELISA Kit) Yourself".