ELISA Kit for Nicotinamide-N-Methyltransferase (NNMT)

  • ELISA Kit for Nicotinamide-N-Methyltransferase (NNMT) Packages (Simulation)
  • ELISA Kit for Nicotinamide-N-Methyltransferase (NNMT) Packages (Simulation)
  • ELISA Kit for Nicotinamide-N-Methyltransferase (NNMT) Results demonstration
  • SEH530Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Nicotinamide-N-Methyltransferase (NNMT)

This assay has high sensitivity and excellent specificity for detection of Nicotinamide-N-Methyltransferase (NNMT).
No significant cross-reactivity or interference between Nicotinamide-N-Methyltransferase (NNMT) and analogues was observed.

Recovery of the ELISA Kit for Nicotinamide-N-Methyltransferase (NNMT)

Matrices listed below were spiked with certain level of recombinant Nicotinamide-N-Methyltransferase (NNMT) and the recovery rates were calculated by comparing the measured value to the expected amount of Nicotinamide-N-Methyltransferase (NNMT) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-101 95
EDTA plasma(n=5) 95-103 99
heparin plasma(n=5) 80-99 91

Precision of the ELISA Kit for Nicotinamide-N-Methyltransferase (NNMT)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Nicotinamide-N-Methyltransferase (NNMT) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Nicotinamide-N-Methyltransferase (NNMT) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Nicotinamide-N-Methyltransferase (NNMT)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Nicotinamide-N-Methyltransferase (NNMT) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-103% 87-95% 80-89% 78-101%
EDTA plasma(n=5) 92-101% 85-102% 96-103% 81-96%
heparin plasma(n=5) 87-94% 94-102% 86-95% 88-96%

Stability of the ELISA Kit for Nicotinamide-N-Methyltransferase (NNMT)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Nicotinamide-N-Methyltransferase (NNMT)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Nicotinamide-N-Methyltransferase (NNMT)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Nicotinamide-N-Methyltransferase (NNMT). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Nicotinamide-N-Methyltransferase (NNMT). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Nicotinamide-N-Methyltransferase (NNMT), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Nicotinamide-N-Methyltransferase (NNMT) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPH530Mu02 Recombinant Nicotinamide-N-Methyltransferase (NNMT) Positive Control; Immunogen; SDS-PAGE; WB.
RPH530Mu01 Recombinant Nicotinamide-N-Methyltransferase (NNMT) Positive Control; Immunogen; SDS-PAGE; WB.
PAH530Mu02 Polyclonal Antibody to Nicotinamide-N-Methyltransferase (NNMT) WB; IHC; ICC; IP.
PAH530Mu01 Polyclonal Antibody to Nicotinamide-N-Methyltransferase (NNMT) WB; IHC; ICC; IP.
LAH530Mu81 FITC-Linked Polyclonal Antibody to Nicotinamide-N-Methyltransferase (NNMT) WB; IHC; ICC; IF.
SEH530Mu ELISA Kit for Nicotinamide-N-Methyltransferase (NNMT) Enzyme-linked immunosorbent assay for Antigen Detection.
LMH530Mu Multiplex Assay Kit for Nicotinamide-N-Methyltransferase (NNMT) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.