ELISA Kit for Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6)

ASD3; MYHC; MYHCA; MyHC-alpha; Cardiomyopathy,Hypertrophic 1; Myosin heavy chain, cardiac muscle alpha isoform

  • ELISA Kit for Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) Packages (Simulation)
  • ELISA Kit for Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) Packages (Simulation)
  • ELISA Kit for Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) Results demonstration
  • SED419Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6)

This assay has high sensitivity and excellent specificity for detection of Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6).
No significant cross-reactivity or interference between Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) and analogues was observed.

Recovery of the ELISA Kit for Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6)

Matrices listed below were spiked with certain level of recombinant Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) and the recovery rates were calculated by comparing the measured value to the expected amount of Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 82-103 86
EDTA plasma(n=5) 95-102 99
heparin plasma(n=5) 95-102 98

Precision of the ELISA Kit for Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-91% 79-102% 94-105% 97-105%
EDTA plasma(n=5) 92-99% 97-104% 78-89% 80-93%
heparin plasma(n=5) 98-105% 92-101% 87-97% 94-101%

Stability of the ELISA Kit for Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPD419Hu01 Recombinant Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) Positive Control; Immunogen; SDS-PAGE; WB.
PAD419Hu01 Polyclonal Antibody to Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) WB; IHC; ICC; IP.
MAD419Hu21 Monoclonal Antibody to Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) WB; IHC; ICC; IP.
SED419Hu ELISA Kit for Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) Enzyme-linked immunosorbent assay for Antigen Detection.
LMD419Hu Multiplex Assay Kit for Myosin Heavy Chain 6, Cardiac Muscle, Alpha (MYH6) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK