ELISA Kit for Leukemia Inhibitory Factor Receptor (LIFR)

CD118; SJS2; STWS; SWS

  • ELISA Kit for Leukemia Inhibitory Factor Receptor (LIFR) Packages (Simulation)
  • ELISA Kit for Leukemia Inhibitory Factor Receptor (LIFR) Packages (Simulation)
  • ELISA Kit for Leukemia Inhibitory Factor Receptor (LIFR) Results demonstration
  • SEA561Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Leukemia Inhibitory Factor Receptor (LIFR)

This assay has high sensitivity and excellent specificity for detection of Leukemia Inhibitory Factor Receptor (LIFR).
No significant cross-reactivity or interference between Leukemia Inhibitory Factor Receptor (LIFR) and analogues was observed.

Recovery of the ELISA Kit for Leukemia Inhibitory Factor Receptor (LIFR)

Matrices listed below were spiked with certain level of recombinant Leukemia Inhibitory Factor Receptor (LIFR) and the recovery rates were calculated by comparing the measured value to the expected amount of Leukemia Inhibitory Factor Receptor (LIFR) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-96 92
EDTA plasma(n=5) 82-97 87
heparin plasma(n=5) 80-90 83

Precision of the ELISA Kit for Leukemia Inhibitory Factor Receptor (LIFR)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Leukemia Inhibitory Factor Receptor (LIFR) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Leukemia Inhibitory Factor Receptor (LIFR) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Leukemia Inhibitory Factor Receptor (LIFR)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Leukemia Inhibitory Factor Receptor (LIFR) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-102% 79-102% 80-95% 78-96%
EDTA plasma(n=5) 87-94% 91-101% 82-96% 80-101%
heparin plasma(n=5) 92-101% 94-101% 87-101% 93-101%

Stability of the ELISA Kit for Leukemia Inhibitory Factor Receptor (LIFR)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Leukemia Inhibitory Factor Receptor (LIFR)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Leukemia Inhibitory Factor Receptor (LIFR)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Leukemia Inhibitory Factor Receptor (LIFR). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Leukemia Inhibitory Factor Receptor (LIFR). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Leukemia Inhibitory Factor Receptor (LIFR), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Leukemia Inhibitory Factor Receptor (LIFR) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA561Mu02 Recombinant Leukemia Inhibitory Factor Receptor (LIFR) Positive Control; Immunogen; SDS-PAGE; WB.
RPA561Mu03 Recombinant Leukemia Inhibitory Factor Receptor (LIFR) Positive Control; Immunogen; SDS-PAGE; WB.
RPA561Mu01 Recombinant Leukemia Inhibitory Factor Receptor (LIFR) Positive Control; Immunogen; SDS-PAGE; WB.
PAA561Mu03 Polyclonal Antibody to Leukemia Inhibitory Factor Receptor (LIFR) WB; IHC; ICC; IP.
PAA561Mu01 Polyclonal Antibody to Leukemia Inhibitory Factor Receptor (LIFR) WB; IHC; ICC; IP.
PAA561Mu02 Polyclonal Antibody to Leukemia Inhibitory Factor Receptor (LIFR) WB; IHC; ICC; IP.
LAA561Mu71 Biotin-Linked Polyclonal Antibody to Leukemia Inhibitory Factor Receptor (LIFR) WB; IHC; ICC.
SEA561Mu ELISA Kit for Leukemia Inhibitory Factor Receptor (LIFR) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA561Mu Multiplex Assay Kit for Leukemia Inhibitory Factor Receptor (LIFR) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK