ELISA Kit for Interleukin 1 Receptor Type I (IL1R1)

CD121a; CD121-A; IL1-R1; IL1R; IL1RA; P80; CD121 Antigen-Like Family Member A; Interleukin-1 Receptor Alpha

  • ELISA Kit for Interleukin 1 Receptor Type I (IL1R1) Packages (Simulation)
  • ELISA Kit for Interleukin 1 Receptor Type I (IL1R1) Packages (Simulation)
  • ELISA Kit for Interleukin 1 Receptor Type I (IL1R1) Results demonstration
  • SEA066Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Interleukin 1 Receptor Type I (IL1R1)

This assay has high sensitivity and excellent specificity for detection of Interleukin 1 Receptor Type I (IL1R1).
No significant cross-reactivity or interference between Interleukin 1 Receptor Type I (IL1R1) and analogues was observed.

Recovery of the ELISA Kit for Interleukin 1 Receptor Type I (IL1R1)

Matrices listed below were spiked with certain level of recombinant Interleukin 1 Receptor Type I (IL1R1) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 1 Receptor Type I (IL1R1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 102
EDTA plasma(n=5) 90-97 93
heparin plasma(n=5) 89-98 93

Precision of the ELISA Kit for Interleukin 1 Receptor Type I (IL1R1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 1 Receptor Type I (IL1R1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 1 Receptor Type I (IL1R1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Interleukin 1 Receptor Type I (IL1R1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 1 Receptor Type I (IL1R1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-99% 82-90% 90-101% 87-96%
EDTA plasma(n=5) 92-101% 78-101% 82-97% 98-105%
heparin plasma(n=5) 78-101% 99-105% 78-89% 90-99%

Stability of the ELISA Kit for Interleukin 1 Receptor Type I (IL1R1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Interleukin 1 Receptor Type I (IL1R1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Interleukin 1 Receptor Type I (IL1R1)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Interleukin 1 Receptor Type I (IL1R1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Interleukin 1 Receptor Type I (IL1R1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Interleukin 1 Receptor Type I (IL1R1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Interleukin 1 Receptor Type I (IL1R1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA066Mu02 Recombinant Interleukin 1 Receptor Type I (IL1R1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA066Mu01 Recombinant Interleukin 1 Receptor Type I (IL1R1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA066Mu02 Polyclonal Antibody to Interleukin 1 Receptor Type I (IL1R1) WB; IHC; ICC; IP.
PAA066Mu01 Polyclonal Antibody to Interleukin 1 Receptor Type I (IL1R1) WB; IHC; ICC; IP.
SEA066Mu ELISA Kit for Interleukin 1 Receptor Type I (IL1R1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA066Mu Multiplex Assay Kit for Interleukin 1 Receptor Type I (IL1R1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA066Mu01 ELISA Kit DIY Materials for Interleukin 1 Receptor Type I (IL1R1) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK