ELISA Kit for Metallothionein 1E (MT1E)

MTD

  • ELISA Kit for Metallothionein 1E (MT1E) Packages (Simulation)
  • ELISA Kit for Metallothionein 1E (MT1E) Packages (Simulation)
  • ELISA Kit for Metallothionein 1E (MT1E) Results demonstration
  • SED794Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Metallothionein 1E (MT1E)

This assay has high sensitivity and excellent specificity for detection of Metallothionein 1E (MT1E).
No significant cross-reactivity or interference between Metallothionein 1E (MT1E) and analogues was observed.

Recovery of the ELISA Kit for Metallothionein 1E (MT1E)

Matrices listed below were spiked with certain level of recombinant Metallothionein 1E (MT1E) and the recovery rates were calculated by comparing the measured value to the expected amount of Metallothionein 1E (MT1E) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-99 86
EDTA plasma(n=5) 95-104 101
heparin plasma(n=5) 80-90 85

Precision of the ELISA Kit for Metallothionein 1E (MT1E)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Metallothionein 1E (MT1E) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Metallothionein 1E (MT1E) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Metallothionein 1E (MT1E)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Metallothionein 1E (MT1E) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 95-102% 78-90% 98-105% 79-103%
EDTA plasma(n=5) 89-103% 85-101% 99-105% 80-102%
heparin plasma(n=5) 90-104% 88-102% 95-103% 93-101%

Stability of the ELISA Kit for Metallothionein 1E (MT1E)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Metallothionein 1E (MT1E)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Metallothionein 1E (MT1E)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Metallothionein 1E (MT1E). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Metallothionein 1E (MT1E). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Metallothionein 1E (MT1E), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Metallothionein 1E (MT1E) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPD794Hu01 Recombinant Metallothionein 1E (MT1E) Positive Control; Immunogen; SDS-PAGE; WB.
PAD794Hu01 Polyclonal Antibody to Metallothionein 1E (MT1E) WB; IHC; ICC; IP.
LAD794Hu81 FITC-Linked Polyclonal Antibody to Metallothionein 1E (MT1E) WB; IHC; ICC; IF.
LAD794Hu71 Biotin-Linked Polyclonal Antibody to Metallothionein 1E (MT1E) WB; IHC; ICC.
MAD794Hu22 Monoclonal Antibody to Metallothionein 1E (MT1E) WB
MAD794Hu21 Monoclonal Antibody to Metallothionein 1E (MT1E) WB
SED794Hu ELISA Kit for Metallothionein 1E (MT1E) Enzyme-linked immunosorbent assay for Antigen Detection.
LMD794Hu Multiplex Assay Kit for Metallothionein 1E (MT1E) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.