ELISA Kit for HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1)

HLA-DRB1; MHCDRb1; HLADRb1; Major Histocompatibility Complex Class II DR Beta 1; HLA Class II Histocompatibility Antigen,DRB1-9 Beta Chain; HLA class II histocompatibility antigen, DRB1-15 beta chain

  • ELISA Kit for HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) Packages (Simulation)
  • ELISA Kit for HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) Packages (Simulation)
  • ELISA Kit for HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) Results demonstration
  • SEC167Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1)

This assay has high sensitivity and excellent specificity for detection of HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1).
No significant cross-reactivity or interference between HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) and analogues was observed.

Recovery of the ELISA Kit for HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1)

Matrices listed below were spiked with certain level of recombinant HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) and the recovery rates were calculated by comparing the measured value to the expected amount of HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-99 96
EDTA plasma(n=5) 80-102 95
heparin plasma(n=5) 78-94 89

Precision of the ELISA Kit for HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-104% 95-105% 79-92% 80-101%
EDTA plasma(n=5) 88-96% 96-103% 85-99% 79-90%
heparin plasma(n=5) 89-96% 97-105% 89-101% 79-94%

Stability of the ELISA Kit for HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPC167Hu01 Recombinant HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC167Hu01 Polyclonal Antibody to HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) WB; IHC
FAC167Hu01 Anti-HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) Polyclonal Antibody Flow cytometry.
FAC167Hu41 PE-Linked Anti-HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) Polyclonal Antibody Flow cytometry.
FAC167Hu51 APC-Linked Anti-HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) Polyclonal Antibody Flow cytometry.
FAC167Hu81 FITC-Linked Anti-HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) Polyclonal Antibody Flow cytometry.
MAC167Hu21 Monoclonal Antibody to HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) WB; IHC
MAC167Hu24 Monoclonal Antibody to HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) WB; IHC; ICC; IP.
MAC167Hu25 Monoclonal Antibody to HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) WB; IHC; ICC; IP.
MAC167Hu23 Monoclonal Antibody to HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) WB; IHC; ICC; IP.
MAC167Hu22 Monoclonal Antibody to HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) WB
SEC167Hu ELISA Kit for HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC167Hu Multiplex Assay Kit for HLA Class II Histocompatibility Antigen, DRB1 Beta Chain (HLA-DRB1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK