ELISA Kit for Insulin Autoantibody (IAA)

Anti-Insulin Antibody; Antiinsulin; Insulin Antibodies

  • ELISA Kit for Insulin Autoantibody (IAA) Packages (Simulation)
  • ELISA Kit for Insulin Autoantibody (IAA) Packages (Simulation)
  • ELISA Kit for Insulin Autoantibody (IAA) Results demonstration
  • AEB264Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Insulin Autoantibody (IAA)

This assay has high sensitivity and excellent specificity for detection of Insulin Autoantibody (IAA).
No significant cross-reactivity or interference between Insulin Autoantibody (IAA) and analogues was observed.

Recovery of the ELISA Kit for Insulin Autoantibody (IAA)

Matrices listed below were spiked with certain level of Insulin Autoantibody (IAA) and the recovery rates were calculated by comparing the measured value to the expected amount of Insulin Autoantibody (IAA) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-89 84
EDTA plasma(n=5) 78-93 83
heparin plasma(n=5) 96-105 99

Precision of the ELISA Kit for Insulin Autoantibody (IAA)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Insulin Autoantibody (IAA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Insulin Autoantibody (IAA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Insulin Autoantibody (IAA)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Insulin Autoantibody (IAA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 78-90% 80-92% 91-105%
EDTA plasma(n=5) 92-104% 87-101% 79-98% 98-105%
heparin plasma(n=5) 79-94% 89-104% 90-99% 95-103%

Stability of the ELISA Kit for Insulin Autoantibody (IAA)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Insulin Autoantibody (IAA)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 5 times;
5. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
6. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Insulin Autoantibody (IAA)

The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated secondary antibody. After TMB substrate solution is added, those wells that contain Insulin Autoantibody (IAA) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Insulin Autoantibody (IAA) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

INCREMENT SERVICES

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
AEB264Mu ELISA Kit for Insulin Autoantibody (IAA) Enzyme-linked immunosorbent assay for Antibody Detection.