ELISA Kit for Paraoxonase 1 (PON1)

ESA; PON; Esterase A; Serum paraoxonase/arylesterase 1; Aromatic esterase 1; A-esterase 1; Serum aryldialkylphosphatase 1

  • ELISA Kit for Paraoxonase 1 (PON1) Packages (Simulation)
  • ELISA Kit for Paraoxonase 1 (PON1) Packages (Simulation)
  • ELISA Kit for Paraoxonase 1 (PON1) Results demonstration
  • SEA243Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Paraoxonase 1 (PON1)

This assay has high sensitivity and excellent specificity for detection of Paraoxonase 1 (PON1).
No significant cross-reactivity or interference between Paraoxonase 1 (PON1) and analogues was observed.

Recovery of the ELISA Kit for Paraoxonase 1 (PON1)

Matrices listed below were spiked with certain level of recombinant Paraoxonase 1 (PON1) and the recovery rates were calculated by comparing the measured value to the expected amount of Paraoxonase 1 (PON1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-97 93
EDTA plasma(n=5) 87-102 93
heparin plasma(n=5) 84-91 88

Precision of the ELISA Kit for Paraoxonase 1 (PON1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Paraoxonase 1 (PON1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Paraoxonase 1 (PON1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Paraoxonase 1 (PON1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Paraoxonase 1 (PON1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-98% 87-101% 84-98% 80-103%
EDTA plasma(n=5) 85-98% 78-93% 89-101% 97-105%
heparin plasma(n=5) 80-90% 80-91% 84-94% 88-101%

Stability of the ELISA Kit for Paraoxonase 1 (PON1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Paraoxonase 1 (PON1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Paraoxonase 1 (PON1)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Paraoxonase 1 (PON1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Paraoxonase 1 (PON1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Paraoxonase 1 (PON1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Paraoxonase 1 (PON1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA243Hu02 Recombinant Paraoxonase 1 (PON1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA243Hu01 Recombinant Paraoxonase 1 (PON1) Positive Control; Immunogen; SDS-PAGE; WB.
APA243Hu01 Active Paraoxonase 1 (PON1) Cell culture; Activity Assays.
RPA243Hu03 Recombinant Paraoxonase 1 (PON1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA243Hu04 Recombinant Paraoxonase 1 (PON1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA243Hu05 Recombinant Paraoxonase 1 (PON1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA243Hu01 Polyclonal Antibody to Paraoxonase 1 (PON1) WB; IHC; ICC; IP.
PAA243Hu02 Polyclonal Antibody to Paraoxonase 1 (PON1) WB; IHC; ICC; IP.
LAA243Hu71 Biotin-Linked Polyclonal Antibody to Paraoxonase 1 (PON1) WB; IHC; ICC.
LAA243Hu81 FITC-Linked Polyclonal Antibody to Paraoxonase 1 (PON1) WB; IHC; ICC; IF.
MAA243Hu22 Monoclonal Antibody to Paraoxonase 1 (PON1) WB; IHC; ICC; IP.
SEA243Hu ELISA Kit for Paraoxonase 1 (PON1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA243Hu CLIA Kit for Paraoxonase 1 (PON1) Chemiluminescent immunoassay for Antigen Detection.
LMA243Hu Multiplex Assay Kit for Paraoxonase 1 (PON1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA243Hu01 ELISA Kit DIY Materials for Paraoxonase 1 (PON1) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK