ELISA Kit for Heat Shock Protein 27 (Hsp27)

HSPB1; HSP-B1; CMT2F; HSP28; Hsp25; Heat Shock 27kDa Protein 1; 28 kDa heat shock protein; Heat shock protein beta-1; Estrogen-regulated 24 kDa protein;

  • ELISA Kit for Heat Shock Protein 27 (Hsp27) Packages (Simulation)
  • ELISA Kit for Heat Shock Protein 27 (Hsp27) Packages (Simulation)
  • ELISA Kit for Heat Shock Protein 27 (Hsp27) Results demonstration
  • SEA693Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Heat Shock Protein 27 (Hsp27)

This assay has high sensitivity and excellent specificity for detection of Heat Shock Protein 27 (Hsp27).
No significant cross-reactivity or interference between Heat Shock Protein 27 (Hsp27) and analogues was observed.

Recovery of the ELISA Kit for Heat Shock Protein 27 (Hsp27)

Matrices listed below were spiked with certain level of recombinant Heat Shock Protein 27 (Hsp27) and the recovery rates were calculated by comparing the measured value to the expected amount of Heat Shock Protein 27 (Hsp27) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-105 102
EDTA plasma(n=5) 80-97 90
heparin plasma(n=5) 78-103 101

Precision of the ELISA Kit for Heat Shock Protein 27 (Hsp27)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Heat Shock Protein 27 (Hsp27) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Heat Shock Protein 27 (Hsp27) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Heat Shock Protein 27 (Hsp27)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Heat Shock Protein 27 (Hsp27) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-94% 80-102% 82-95% 93-104%
EDTA plasma(n=5) 78-101% 90-97% 78-101% 84-92%
heparin plasma(n=5) 93-101% 80-101% 90-97% 84-91%

Stability of the ELISA Kit for Heat Shock Protein 27 (Hsp27)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Heat Shock Protein 27 (Hsp27)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Heat Shock Protein 27 (Hsp27)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Heat Shock Protein 27 (Hsp27). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Heat Shock Protein 27 (Hsp27). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Heat Shock Protein 27 (Hsp27), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Heat Shock Protein 27 (Hsp27) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
EPA693Hu61 Eukaryotic Heat Shock Protein 27 (Hsp27) Positive Control; Immunogen; SDS-PAGE; WB.
RPA693Hu01 Recombinant Heat Shock Protein 27 (Hsp27) Positive Control; Immunogen; SDS-PAGE; WB.
APA693Hu61 Active Heat Shock Protein 27 (Hsp27) Cell culture; Activity Assays.
PAA693Hu01 Polyclonal Antibody to Heat Shock Protein 27 (Hsp27) WB,IHC,ICC/IF
LAA693Hu81 FITC-Linked Polyclonal Antibody to Heat Shock Protein 27 (Hsp27) WB; IHC; ICC; IF.
LAA693Hu71 Biotin-Linked Polyclonal Antibody to Heat Shock Protein 27 (Hsp27) WB; IHC; ICC.
FAA693Hu81 FITC-Linked Anti-Heat Shock Protein 27 (Hsp27) Polyclonal Antibody Flow cytometry.
MAA693Hu22 Monoclonal Antibody to Heat Shock Protein 27 (Hsp27) WB; IHC; ICC; IP.
MAA693Hu21 Monoclonal Antibody to Heat Shock Protein 27 (Hsp27) WB; IHC; ICC; IP.
MAA693Hu23 Monoclonal Antibody to Heat Shock Protein 27 (Hsp27) WB; IHC
MAA693Hu24 Monoclonal Antibody to Heat Shock Protein 27 (Hsp27) WB; IHC; ICC; IP.
MAA693Hu25 Monoclonal Antibody to Heat Shock Protein 27 (Hsp27) WB; IHC; ICC; IP.
MAA693Hu27 Monoclonal Antibody to Heat Shock Protein 27 (Hsp27) WB; IHC; ICC; IP.
MAA693Hu29 Monoclonal Antibody to Heat Shock Protein 27 (Hsp27) WB; IHC; ICC; IP.
FAA693Hu06 Anti-Heat Shock Protein 27 (Hsp27) Monoclonal Antibody Flow cytometry.
FAA693Hu08 Anti-Heat Shock Protein 27 (Hsp27) Monoclonal Antibody Flow cytometry.
FAA693Hu04 Anti-Heat Shock Protein 27 (Hsp27) Monoclonal Antibody Flow cytometry.
FAA693Hu02 Anti-Heat Shock Protein 27 (Hsp27) Monoclonal Antibody Flow cytometry.
LAA693Hu74 Biotin-Linked Monoclonal Antibody to Heat Shock Protein 27 (Hsp27) WB; IHC; ICC.
SEA693Hu ELISA Kit for Heat Shock Protein 27 (Hsp27) Enzyme-linked immunosorbent assay for Antigen Detection.
HEA693Hu High Sensitive ELISA Kit for Heat Shock Protein 27 (Hsp27) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA693Hu Multiplex Assay Kit for Heat Shock Protein 27 (Hsp27) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA693Hu01 ELISA Kit DIY Materials for Heat Shock Protein 27 (Hsp27) Main materials for "Do It(ELISA Kit) Yourself"
GUESTBOOK