ELISA Kit for Fibroblast Growth Factor 21 (FGF21)

  • ELISA Kit for Fibroblast Growth Factor 21 (FGF21) Packages (Simulation)
  • ELISA Kit for Fibroblast Growth Factor 21 (FGF21) Packages (Simulation)
  • ELISA Kit for Fibroblast Growth Factor 21 (FGF21) Results demonstration
  • SEC918Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Fibroblast Growth Factor 21 (FGF21)

This assay has high sensitivity and excellent specificity for detection of Fibroblast Growth Factor 21 (FGF21).
No significant cross-reactivity or interference between Fibroblast Growth Factor 21 (FGF21) and analogues was observed.

Recovery of the ELISA Kit for Fibroblast Growth Factor 21 (FGF21)

Matrices listed below were spiked with certain level of recombinant Fibroblast Growth Factor 21 (FGF21) and the recovery rates were calculated by comparing the measured value to the expected amount of Fibroblast Growth Factor 21 (FGF21) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-94 91
EDTA plasma(n=5) 87-94 91
heparin plasma(n=5) 99-105 102

Precision of the ELISA Kit for Fibroblast Growth Factor 21 (FGF21)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibroblast Growth Factor 21 (FGF21) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibroblast Growth Factor 21 (FGF21) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Fibroblast Growth Factor 21 (FGF21)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Fibroblast Growth Factor 21 (FGF21) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-92% 83-91% 96-105% 89-97%
EDTA plasma(n=5) 80-102% 89-97% 81-91% 80-89%
heparin plasma(n=5) 90-101% 97-105% 81-98% 80-103%

Stability of the ELISA Kit for Fibroblast Growth Factor 21 (FGF21)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Fibroblast Growth Factor 21 (FGF21)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Fibroblast Growth Factor 21 (FGF21)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Fibroblast Growth Factor 21 (FGF21). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Fibroblast Growth Factor 21 (FGF21). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Fibroblast Growth Factor 21 (FGF21), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Fibroblast Growth Factor 21 (FGF21) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPC918Hu01 Recombinant Fibroblast Growth Factor 21 (FGF21) Positive Control; Immunogen; SDS-PAGE; WB.
APC918Hu61 Active Fibroblast Growth Factor 21 (FGF21) Cell culture; Activity Assays.
EPC918Hu61 Eukaryotic Fibroblast Growth Factor 21 (FGF21) Positive Control; Immunogen; SDS-PAGE; WB.
APC918Hu01 Active Fibroblast Growth Factor 21 (FGF21) Cell culture; Activity Assays.
PAC918Hu01 Polyclonal Antibody to Fibroblast Growth Factor 21 (FGF21) WB; IHC; ICC; IP.
FAC918Hu01 Anti-Fibroblast Growth Factor 21 (FGF21) Polyclonal Antibody Flow cytometry.
MAC918Hu21 Monoclonal Antibody to Fibroblast Growth Factor 21 (FGF21) WB; IHC; ICC; IP.
MAC918Hu23 Monoclonal Antibody to Fibroblast Growth Factor 21 (FGF21) WB; IHC; ICC; IP.
MAC918Hu24 Monoclonal Antibody to Fibroblast Growth Factor 21 (FGF21) WB; IHC; ICC; IP.
MAC918Hu22 Monoclonal Antibody to Fibroblast Growth Factor 21 (FGF21) WB; IHC; ICC; IP.
MAC918Hu25 Monoclonal Antibody to Fibroblast Growth Factor 21 (FGF21) WB; IHC; ICC; IP.
MAC918Hu27 Monoclonal Antibody to Fibroblast Growth Factor 21 (FGF21) WB; IHC; ICC; IP.
SEC918Hu ELISA Kit for Fibroblast Growth Factor 21 (FGF21) Enzyme-linked immunosorbent assay for Antigen Detection.
MEC918Hu Mini Samples ELISA Kit for Fibroblast Growth Factor 21 (FGF21) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC918Hu CLIA Kit for Fibroblast Growth Factor 21 (FGF21) Chemiluminescent immunoassay for Antigen Detection.
CCC918Hu CLIA Kit for Fibroblast Growth Factor 21 (FGF21) Chemiluminescent immunoassay for Antigen Detection.
LMC918Hu Multiplex Assay Kit for Fibroblast Growth Factor 21 (FGF21) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK