ELISA Kit for Collagen Type XI Alpha 1 (COL11a1)

COL11-A1; CO11A1; COLL6; STL2; Collagen Alpha-1(XI)chain

  • ELISA Kit for Collagen Type XI Alpha 1 (COL11a1) Packages (Simulation)
  • ELISA Kit for Collagen Type XI Alpha 1 (COL11a1) Packages (Simulation)
  • ELISA Kit for Collagen Type XI Alpha 1 (COL11a1) Results demonstration
  • SEC157Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Collagen Type XI Alpha 1 (COL11a1)

This assay has high sensitivity and excellent specificity for detection of Collagen Type XI Alpha 1 (COL11a1).
No significant cross-reactivity or interference between Collagen Type XI Alpha 1 (COL11a1) and analogues was observed.

Recovery of the ELISA Kit for Collagen Type XI Alpha 1 (COL11a1)

Matrices listed below were spiked with certain level of recombinant Collagen Type XI Alpha 1 (COL11a1) and the recovery rates were calculated by comparing the measured value to the expected amount of Collagen Type XI Alpha 1 (COL11a1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-95 89
EDTA plasma(n=5) 88-97 92
heparin plasma(n=5) 91-101 97

Precision of the ELISA Kit for Collagen Type XI Alpha 1 (COL11a1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Collagen Type XI Alpha 1 (COL11a1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Collagen Type XI Alpha 1 (COL11a1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Collagen Type XI Alpha 1 (COL11a1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Collagen Type XI Alpha 1 (COL11a1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-104% 98-105% 81-99% 81-95%
EDTA plasma(n=5) 82-103% 88-102% 88-95% 96-105%
heparin plasma(n=5) 78-101% 80-104% 85-101% 97-105%

Stability of the ELISA Kit for Collagen Type XI Alpha 1 (COL11a1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Collagen Type XI Alpha 1 (COL11a1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Collagen Type XI Alpha 1 (COL11a1)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Collagen Type XI Alpha 1 (COL11a1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Collagen Type XI Alpha 1 (COL11a1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Collagen Type XI Alpha 1 (COL11a1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Collagen Type XI Alpha 1 (COL11a1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPC157Hu01 Recombinant Collagen Type XI Alpha 1 (COL11a1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC157Hu02 Recombinant Collagen Type XI Alpha 1 (COL11a1) Positive Control; Immunogen; SDS-PAGE; WB.
CPC157Hu21 OVA Conjugated Collagen Type XI Alpha 1 (COL11a1) Immunogen; SDS-PAGE; WB.
PAC157Hu01 Polyclonal Antibody to Collagen Type XI Alpha 1 (COL11a1) WB; IHC; ICC; IP.
MAC157Hu22 Monoclonal Antibody to Collagen Type XI Alpha 1 (COL11a1) WB; IHC; ICC; IP.
SEC157Hu ELISA Kit for Collagen Type XI Alpha 1 (COL11a1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC157Hu Multiplex Assay Kit for Collagen Type XI Alpha 1 (COL11a1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK