ELISA Kit for Chemokine C-C-Motif Receptor 2 (CCR2)

CD192; CC-CKR2; CCR2A; C-C CKR-2; CCR2B; CKR2-A; CKR2-B; CMKBR2; MCP1-R; Monocyte chemoattractant protein 1 receptor

  • ELISA Kit for Chemokine C-C-Motif Receptor 2 (CCR2) Packages (Simulation)
  • ELISA Kit for Chemokine C-C-Motif Receptor 2 (CCR2) Packages (Simulation)
  • ELISA Kit for Chemokine C-C-Motif Receptor 2 (CCR2) Results demonstration
  • SEA914Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Chemokine C-C-Motif Receptor 2 (CCR2)

This assay has high sensitivity and excellent specificity for detection of Chemokine C-C-Motif Receptor 2 (CCR2).
No significant cross-reactivity or interference between Chemokine C-C-Motif Receptor 2 (CCR2) and analogues was observed.

Recovery of the ELISA Kit for Chemokine C-C-Motif Receptor 2 (CCR2)

Matrices listed below were spiked with certain level of recombinant Chemokine C-C-Motif Receptor 2 (CCR2) and the recovery rates were calculated by comparing the measured value to the expected amount of Chemokine C-C-Motif Receptor 2 (CCR2) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-101 97
EDTA plasma(n=5) 96-103 101
heparin plasma(n=5) 80-102 95

Precision of the ELISA Kit for Chemokine C-C-Motif Receptor 2 (CCR2)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemokine C-C-Motif Receptor 2 (CCR2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemokine C-C-Motif Receptor 2 (CCR2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Chemokine C-C-Motif Receptor 2 (CCR2)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chemokine C-C-Motif Receptor 2 (CCR2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-102% 90-97% 84-97% 90-103%
EDTA plasma(n=5) 89-98% 78-104% 79-91% 87-94%
heparin plasma(n=5) 90-97% 83-95% 88-95% 93-101%

Stability of the ELISA Kit for Chemokine C-C-Motif Receptor 2 (CCR2)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Chemokine C-C-Motif Receptor 2 (CCR2)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Chemokine C-C-Motif Receptor 2 (CCR2)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Chemokine C-C-Motif Receptor 2 (CCR2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Chemokine C-C-Motif Receptor 2 (CCR2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Chemokine C-C-Motif Receptor 2 (CCR2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Chemokine C-C-Motif Receptor 2 (CCR2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA914Hu01 Recombinant Chemokine C-C-Motif Receptor 2 (CCR2) Positive Control; Immunogen; SDS-PAGE; WB.
PAA914Hu01 Polyclonal Antibody to Chemokine C-C-Motif Receptor 2 (CCR2) WB; IHC; ICC; IP.
MAA914Hu22 Monoclonal Antibody to Chemokine C-C-Motif Receptor 2 (CCR2) WB; IHC; ICC; IP.
RAA914Hu21 Recombinant Antibody to Chemokine C-C-Motif Receptor 2 (CCR2) WB; IF; ICC; IHC; IP; FCM.
SEA914Hu ELISA Kit for Chemokine C-C-Motif Receptor 2 (CCR2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA914Hu Multiplex Assay Kit for Chemokine C-C-Motif Receptor 2 (CCR2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK