ELISA Kit for Alanine Aminopeptidase (AAP)

CD13; ALAP; P150; ANPEP; APN; LAP1; PEPN; Gp150; Aminopeptidase M; Microsomal Aminopeptidase; Alanyl Membrane Aminopeptidase; Aminopeptidase N

  • ELISA Kit for Alanine Aminopeptidase (AAP) Packages (Simulation)
  • ELISA Kit for Alanine Aminopeptidase (AAP) Packages (Simulation)
  • ELISA Kit for Alanine Aminopeptidase (AAP) Results demonstration
  • SEB065Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Alanine Aminopeptidase (AAP)

This assay has high sensitivity and excellent specificity for detection of Alanine Aminopeptidase (AAP).
No significant cross-reactivity or interference between Alanine Aminopeptidase (AAP) and analogues was observed.

Recovery of the ELISA Kit for Alanine Aminopeptidase (AAP)

Matrices listed below were spiked with certain level of recombinant Alanine Aminopeptidase (AAP) and the recovery rates were calculated by comparing the measured value to the expected amount of Alanine Aminopeptidase (AAP) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-104 96
EDTA plasma(n=5) 82-89 85
heparin plasma(n=5) 78-102 85

Precision of the ELISA Kit for Alanine Aminopeptidase (AAP)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Alanine Aminopeptidase (AAP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Alanine Aminopeptidase (AAP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Alanine Aminopeptidase (AAP)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Alanine Aminopeptidase (AAP) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 95-105% 79-101% 88-96%
EDTA plasma(n=5) 83-103% 95-104% 85-104% 95-104%
heparin plasma(n=5) 80-92% 81-98% 97-105% 88-96%

Stability of the ELISA Kit for Alanine Aminopeptidase (AAP)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Alanine Aminopeptidase (AAP)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Alanine Aminopeptidase (AAP)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Alanine Aminopeptidase (AAP). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Alanine Aminopeptidase (AAP). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Alanine Aminopeptidase (AAP), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Alanine Aminopeptidase (AAP) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
EPB065Hu61 Eukaryotic Alanine Aminopeptidase (AAP) Positive Control; Immunogen; SDS-PAGE; WB.
APB065Hu61 Active Alanine Aminopeptidase (AAP) Cell culture; Activity Assays.
RPB065Hu01 Recombinant Alanine Aminopeptidase (AAP) Positive Control; Immunogen; SDS-PAGE; WB.
RPB065Hu02 Recombinant Alanine Aminopeptidase (AAP) Positive Control; Immunogen; SDS-PAGE; WB.
PAB065Hu01 Polyclonal Antibody to Alanine Aminopeptidase (AAP) WB; IHC; ICC; IP.
MAB065Hu21 Monoclonal Antibody to Alanine Aminopeptidase (AAP) WB; IHC; ICC; IP.
MAB065Hu22 Monoclonal Antibody to Alanine Aminopeptidase (AAP) WB; IHC; ICC; IP.
MAB065Hu26 Monoclonal Antibody to Alanine Aminopeptidase (AAP) WB; IHC; ICC; IP.
FAB065Hu02 Anti-Alanine Aminopeptidase (AAP) Monoclonal Antibody FCM
FAB065Hu04 Anti-Alanine Aminopeptidase (AAP) Monoclonal Antibody FCM
SEB065Hu ELISA Kit for Alanine Aminopeptidase (AAP) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB065Hu Multiplex Assay Kit for Alanine Aminopeptidase (AAP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK