ELISA Kit for B-Lymphocyte Chemoattractant (BLC)

CXCL13; SCYB13; BCA1; BLR1L; ANGIE; ANGIE2; Chemokine(C-X-C-Motif)ligand 13; Small Inducible Cytokine B Subfamily(Cys-X-Cys Motif)Member 13

  • ELISA Kit for B-Lymphocyte Chemoattractant (BLC) Packages (Simulation)
  • ELISA Kit for B-Lymphocyte Chemoattractant (BLC) Packages (Simulation)
  • ELISA Kit for B-Lymphocyte Chemoattractant (BLC) Results demonstration
  • SEB601Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for B-Lymphocyte Chemoattractant (BLC)

This assay has high sensitivity and excellent specificity for detection of B-Lymphocyte Chemoattractant (BLC).
No significant cross-reactivity or interference between B-Lymphocyte Chemoattractant (BLC) and analogues was observed.

Recovery of the ELISA Kit for B-Lymphocyte Chemoattractant (BLC)

Matrices listed below were spiked with certain level of recombinant B-Lymphocyte Chemoattractant (BLC) and the recovery rates were calculated by comparing the measured value to the expected amount of B-Lymphocyte Chemoattractant (BLC) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-97 93
EDTA plasma(n=5) 79-103 81
heparin plasma(n=5) 87-94 91

Precision of the ELISA Kit for B-Lymphocyte Chemoattractant (BLC)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level B-Lymphocyte Chemoattractant (BLC) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level B-Lymphocyte Chemoattractant (BLC) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for B-Lymphocyte Chemoattractant (BLC)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of B-Lymphocyte Chemoattractant (BLC) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-104% 81-96% 98-105% 96-103%
EDTA plasma(n=5) 84-95% 86-93% 98-105% 83-93%
heparin plasma(n=5) 90-104% 87-96% 82-94% 96-104%

Stability of the ELISA Kit for B-Lymphocyte Chemoattractant (BLC)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for B-Lymphocyte Chemoattractant (BLC)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for B-Lymphocyte Chemoattractant (BLC)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to B-Lymphocyte Chemoattractant (BLC). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to B-Lymphocyte Chemoattractant (BLC). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain B-Lymphocyte Chemoattractant (BLC), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of B-Lymphocyte Chemoattractant (BLC) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
RPB601Ra01 Recombinant B-Lymphocyte Chemoattractant (BLC) Positive Control; Immunogen; SDS-PAGE; WB.
PAB601Ra01 Polyclonal Antibody to B-Lymphocyte Chemoattractant (BLC) WB; IHC; ICC; IP.
MAB601Ra21 Monoclonal Antibody to B-Lymphocyte Chemoattractant (BLC) WB; IHC; ICC; IP.
SEB601Ra ELISA Kit for B-Lymphocyte Chemoattractant (BLC) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB601Ra CLIA Kit for B-Lymphocyte Chemoattractant (BLC) Chemiluminescent immunoassay for Antigen Detection.
LMB601Ra Multiplex Assay Kit for B-Lymphocyte Chemoattractant (BLC) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK