ELISA Kit for Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH)

GNRH1; GRH; LNRH; LHRH; LH-RH I; Luliberin; Luteinizing-Hormone Releasing Hormone; Progonadoliberin-1; Gonadoliberin I; Gonadorelin; GnRH-associated peptide 1

  • ELISA Kit for Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH) Packages (Simulation)
  • ELISA Kit for Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH) Packages (Simulation)
  • ELISA Kit for Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH) Results demonstration
  • AEA843Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH)

This assay has high sensitivity and excellent specificity for detection of Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH).
No significant cross-reactivity or interference between Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH) and analogues was observed.

Recovery of the ELISA Kit for Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH)

Matrices listed below were spiked with certain level of Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH) and the recovery rates were calculated by comparing the measured value to the expected amount of Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-105 101
EDTA plasma(n=5) 80-99 87
heparin plasma(n=5) 87-101 95

Precision of the ELISA Kit for Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-92% 88-95% 97-105% 80-95%
EDTA plasma(n=5) 79-102% 90-97% 79-99% 78-98%
heparin plasma(n=5) 82-97% 80-93% 98-105% 88-95%

Stability of the ELISA Kit for Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 5 times;
5. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
6. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH)

The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated secondary antibody. After TMB substrate solution is added, those wells that contain Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA843Mu01 Recombinant Gonadotropin Releasing Hormone (GnRH) Positive Control; Immunogen; SDS-PAGE; WB.
RPA843Mu02 Recombinant Gonadotropin Releasing Hormone (GnRH) Positive Control; Immunogen; SDS-PAGE; WB.
PAA843Mu01 Polyclonal Antibody to Gonadotropin Releasing Hormone (GnRH) WB; IHC; ICC; IP.
PAA843Mu02 Polyclonal Antibody to Gonadotropin Releasing Hormone (GnRH) WB; IHC; ICC; IP.
LAA843Mu71 Biotin-Linked Polyclonal Antibody to Gonadotropin Releasing Hormone (GnRH) WB; IHC; ICC.
LAA843Mu81 FITC-Linked Polyclonal Antibody to Gonadotropin Releasing Hormone (GnRH) WB; IHC; ICC; IF.
CEA843Mu ELISA Kit for Gonadotropin Releasing Hormone (GnRH) Enzyme-linked immunosorbent assay for Antigen Detection.
AEA843Mu ELISA Kit for Anti-Gonadotropin Releasing Hormone Antibody (Anti-GnRH) Enzyme-linked immunosorbent assay for Antibody Detection.
CCA843Mu CLIA Kit for Gonadotropin Releasing Hormone (GnRH) Chemiluminescent immunoassay for Antigen Detection.
KSA843Mu11 ELISA Kit DIY Materials for Gonadotropin Releasing Hormone (GnRH) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK