CLIA Kit for Very Low Density Lipoprotein Receptor (VLDLR)

VLDL-R

  • CLIA Kit for Very Low Density Lipoprotein Receptor (VLDLR) Packages (Simulation)
  • CLIA Kit for Very Low Density Lipoprotein Receptor (VLDLR) Packages (Simulation)
  • CLIA Kit for Very Low Density Lipoprotein Receptor (VLDLR) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Very Low Density Lipoprotein Receptor (VLDLR)

This assay has high sensitivity and excellent specificity for detection of Very Low Density Lipoprotein Receptor (VLDLR).
No significant cross-reactivity or interference between Very Low Density Lipoprotein Receptor (VLDLR) and analogues was observed.

Precision of the CLIA Kit for Very Low Density Lipoprotein Receptor (VLDLR)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Very Low Density Lipoprotein Receptor (VLDLR) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Very Low Density Lipoprotein Receptor (VLDLR) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the CLIA Kit for Very Low Density Lipoprotein Receptor (VLDLR)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Very Low Density Lipoprotein Receptor (VLDLR)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Very Low Density Lipoprotein Receptor (VLDLR)

The microplate provided in this kit has been pre-coated with an antibody specific to Very Low Density Lipoprotein Receptor (VLDLR). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Very Low Density Lipoprotein Receptor (VLDLR). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Very Low Density Lipoprotein Receptor (VLDLR) level in the sample or standard.;

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
RPB009Ra01 Recombinant Very Low Density Lipoprotein Receptor (VLDLR) Positive Control; Immunogen; SDS-PAGE; WB.
PAB009Ra01 Polyclonal Antibody to Very Low Density Lipoprotein Receptor (VLDLR) WB; IHC; ICC; IP.
MAB009Ra21 Monoclonal Antibody to Very Low Density Lipoprotein Receptor (VLDLR) WB; IHC; ICC; IP.
SEB009Ra ELISA Kit for Very Low Density Lipoprotein Receptor (VLDLR) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB009Ra CLIA Kit for Very Low Density Lipoprotein Receptor (VLDLR) Chemiluminescent immunoassay for Antigen Detection.
LMB009Ra Multiplex Assay Kit for Very Low Density Lipoprotein Receptor (VLDLR) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.