CLIA Kit for Protein C Inhibitor (PCI)

SERPINA5; PAI3; PLANH3; PROCI; Serpin Peptidase Inhibitor Clade A 5; Plasma Serine Protease Inhibitor; Plasminogen Activator Inhibitor 3; Acrosomal serine protease inhibitor

  • CLIA Kit for Protein C Inhibitor (PCI) Packages (Simulation)
  • CLIA Kit for Protein C Inhibitor (PCI) Packages (Simulation)
  • CLIA Kit for Protein C Inhibitor (PCI) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Protein C Inhibitor (PCI)

This assay has high sensitivity and excellent specificity for detection of Protein C Inhibitor (PCI).
No significant cross-reactivity or interference between Protein C Inhibitor (PCI) and analogues was observed.

Recovery of the CLIA Kit for Protein C Inhibitor (PCI)

Matrices listed below were spiked with certain level of recombinant Protein C Inhibitor (PCI) and the recovery rates were calculated by comparing the measured value to the expected amount of Protein C Inhibitor (PCI) in samples.

Matrix Recovery range (%) Average(%)
sodium citrate plasma(n=5) 87-96 91

Precision of the CLIA Kit for Protein C Inhibitor (PCI)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Protein C Inhibitor (PCI) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Protein C Inhibitor (PCI) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Protein C Inhibitor (PCI)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Protein C Inhibitor (PCI) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
sodium citrate plasma(n=5) 91-104% 81-101% 78-99% 78-98%

Stability of the CLIA Kit for Protein C Inhibitor (PCI)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Protein C Inhibitor (PCI)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Protein C Inhibitor (PCI)

The microplate provided in this kit has been pre-coated with an antibody specific to Protein C Inhibitor (PCI). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Protein C Inhibitor (PCI). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Protein C Inhibitor (PCI) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPD393Hu01 Recombinant Protein C Inhibitor (PCI) Positive Control; Immunogen; SDS-PAGE; WB.
PAD393Hu01 Polyclonal Antibody to Protein C Inhibitor (PCI) WB; ICC; IHC-P; IHC-F; ELISA.
MAD393Hu21 Monoclonal Antibody to Protein C Inhibitor (PCI) WB; IHC; ICC; IP.
SED393Hu ELISA Kit for Protein C Inhibitor (PCI) Enzyme-linked immunosorbent assay for Antigen Detection.
SCD393Hu CLIA Kit for Protein C Inhibitor (PCI) Chemiluminescent immunoassay for Antigen Detection.
LMD393Hu Multiplex Assay Kit for Protein C Inhibitor (PCI) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.