CLIA Kit for Platelet Factor 4 (PF4)

CXCL4; SCYB4; Chemokine C-X-C-Motif Ligand 4; Oncostatin-A; Iroplact

  • CLIA Kit for Platelet Factor 4 (PF4) Packages (Simulation)
  • CLIA Kit for Platelet Factor 4 (PF4) Packages (Simulation)
  • CLIA Kit for Platelet Factor 4 (PF4) Results demonstration
  • SCA172Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Platelet Factor 4 (PF4)

This assay has high sensitivity and excellent specificity for detection of Platelet Factor 4 (PF4).
No significant cross-reactivity or interference between Platelet Factor 4 (PF4) and analogues was observed.

Recovery of the CLIA Kit for Platelet Factor 4 (PF4)

Matrices listed below were spiked with certain level of recombinant Platelet Factor 4 (PF4) and the recovery rates were calculated by comparing the measured value to the expected amount of Platelet Factor 4 (PF4) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-103 98
EDTA plasma(n=5) 91-104 101
heparin plasma(n=5) 93-102 96

Precision of the CLIA Kit for Platelet Factor 4 (PF4)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Platelet Factor 4 (PF4) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Platelet Factor 4 (PF4) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Platelet Factor 4 (PF4)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Platelet Factor 4 (PF4) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-95% 83-97% 84-92% 95-102%
EDTA plasma(n=5) 89-96% 89-96% 95-104% 86-104%
heparin plasma(n=5) 85-98% 89-96% 90-98% 94-103%

Stability of the CLIA Kit for Platelet Factor 4 (PF4)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Platelet Factor 4 (PF4)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Platelet Factor 4 (PF4)

The microplate provided in this kit has been pre-coated with an antibody specific to Platelet Factor 4 (PF4). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Platelet Factor 4 (PF4). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Platelet Factor 4 (PF4) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APA172Hu01 Active Platelet Factor 4 (PF4) Cell culture; Activity Assays.
RPA172Hu01 Recombinant Platelet Factor 4 (PF4) Positive Control; Immunogen; SDS-PAGE; WB.
RPA172Hu02 Recombinant Platelet Factor 4 (PF4) Positive Control; Immunogen; SDS-PAGE; WB.
PAA172Hu01 Polyclonal Antibody to Platelet Factor 4 (PF4) WB; IHC; ICC; IP.
LAA172Hu71 Biotin-Linked Polyclonal Antibody to Platelet Factor 4 (PF4) WB; IHC; ICC.
LAA172Hu81 FITC-Linked Polyclonal Antibody to Platelet Factor 4 (PF4) WB; IHC; ICC; IF.
MAA172Hu21 Monoclonal Antibody to Platelet Factor 4 (PF4) WB; IHC; ICC; IP.
MAA172Hu23 Monoclonal Antibody to Platelet Factor 4 (PF4) WB; IHC; ICC; IP.
MAA172Hu24 Monoclonal Antibody to Platelet Factor 4 (PF4) WB; IHC; ICC; IP.
MAA172Hu22 Monoclonal Antibody to Platelet Factor 4 (PF4) WB; IHC
SEA172Hu ELISA Kit for Platelet Factor 4 (PF4) Enzyme-linked immunosorbent assay for Antigen Detection.
AEA172Hu ELISA Kit for Anti-Platelet Factor 4 Antibody (Anti-PF4) Enzyme-linked immunosorbent assay for Antibody Detection.
SCA172Hu CLIA Kit for Platelet Factor 4 (PF4) Chemiluminescent immunoassay for Antigen Detection.
LMA172Hu Multiplex Assay Kit for Platelet Factor 4 (PF4) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSA172Hu01 Antibody Pair for Platelet Factor 4 (PF4) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.