CLIA Kit for Mucin 5 Subtype AC (MUC5AC)

TBM; MUC5; LeB; Oligomeric Mucus/Gel-Forming; Mucin 5,Subtypes A And C,Tracheobronchial/Gastric; Gastric mucin; Lewis B blood group antigen; Major airway glycoprotein

  • CLIA Kit for Mucin 5 Subtype AC (MUC5AC) Packages (Simulation)
  • CLIA Kit for Mucin 5 Subtype AC (MUC5AC) Packages (Simulation)
  • CLIA Kit for Mucin 5 Subtype AC (MUC5AC) Results demonstration
  • SCA756Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Mucin 5 Subtype AC (MUC5AC)

This assay has high sensitivity and excellent specificity for detection of Mucin 5 Subtype AC (MUC5AC).
No significant cross-reactivity or interference between Mucin 5 Subtype AC (MUC5AC) and analogues was observed.

Precision of the CLIA Kit for Mucin 5 Subtype AC (MUC5AC)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mucin 5 Subtype AC (MUC5AC) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mucin 5 Subtype AC (MUC5AC) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the CLIA Kit for Mucin 5 Subtype AC (MUC5AC)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Mucin 5 Subtype AC (MUC5AC)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Mucin 5 Subtype AC (MUC5AC)

The microplate provided in this kit has been pre-coated with an antibody specific to Mucin 5 Subtype AC (MUC5AC). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Mucin 5 Subtype AC (MUC5AC). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Mucin 5 Subtype AC (MUC5AC) level in the sample or standard.;

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
RPA756Ra01 Recombinant Mucin 5 Subtype AC (MUC5AC) Positive Control; Immunogen; SDS-PAGE; WB.
RPA756Ra02 Recombinant Mucin 5 Subtype AC (MUC5AC) Positive Control; Immunogen; SDS-PAGE; WB.
PAA756Ra01 Polyclonal Antibody to Mucin 5 Subtype AC (MUC5AC) WB; IHC; ICC; IP.
PAA756Ra02 Polyclonal Antibody to Mucin 5 Subtype AC (MUC5AC) WB; IHC; ICC; IP.
LAA756Ra71 Biotin-Linked Polyclonal Antibody to Mucin 5 Subtype AC (MUC5AC) WB; IHC; ICC.
MAA756Ra21 Monoclonal Antibody to Mucin 5 Subtype AC (MUC5AC) WB; IHC; ICC; IP.
SEA756Ra ELISA Kit for Mucin 5 Subtype AC (MUC5AC) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA756Ra CLIA Kit for Mucin 5 Subtype AC (MUC5AC) Chemiluminescent immunoassay for Antigen Detection.
LMA756Ra Multiplex Assay Kit for Mucin 5 Subtype AC (MUC5AC) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.