CLIA Kit for Fibroblast Growth Factor 18 (FGF18)

ZFGF5

  • CLIA Kit for Fibroblast Growth Factor 18 (FGF18) Packages (Simulation)
  • CLIA Kit for Fibroblast Growth Factor 18 (FGF18) Packages (Simulation)
  • CLIA Kit for Fibroblast Growth Factor 18 (FGF18) Results demonstration
  • CCC907Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)

This assay has high sensitivity and excellent specificity for detection of Fibroblast Growth Factor 18 (FGF18).
No significant cross-reactivity or interference between Fibroblast Growth Factor 18 (FGF18) and analogues was observed.

Recovery of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)

Matrices listed below were spiked with certain level of recombinant Fibroblast Growth Factor 18 (FGF18) and the recovery rates were calculated by comparing the measured value to the expected amount of Fibroblast Growth Factor 18 (FGF18) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-105 101
EDTA plasma(n=5) 79-95 82
heparin plasma(n=5) 78-89 82

Precision of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibroblast Growth Factor 18 (FGF18) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibroblast Growth Factor 18 (FGF18) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Fibroblast Growth Factor 18 (FGF18) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 93-103% 95-102% 93-101% 87-95%
EDTA plasma(n=5) 79-99% 93-104% 79-95% 85-92%
heparin plasma(n=5) 78-95% 96-104% 98-105% 93-101%

Stability of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.

Test principle of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)

The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Fibroblast Growth Factor 18 (FGF18). A competitive inhibition reaction is launched between biotin labeled Fibroblast Growth Factor 18 (FGF18) and unlabeled Fibroblast Growth Factor 18 (FGF18) (Standards or samples) with the pre-coated antibody specific to Fibroblast Growth Factor 18 (FGF18). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Fibroblast Growth Factor 18 (FGF18) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Fibroblast Growth Factor 18 (FGF18) level in the sample or standard.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
EPC907Hu62 Eukaryotic Fibroblast Growth Factor 18 (FGF18) Positive Control; Immunogen; SDS-PAGE; WB.
RPC907Hu02 Recombinant Fibroblast Growth Factor 18 (FGF18) Positive Control; Immunogen; SDS-PAGE; WB.
APC907Hu02 Active Fibroblast Growth Factor 18 (FGF18) Cell culture; Activity Assays.
RPC907Hu01 Recombinant Fibroblast Growth Factor 18 (FGF18) Positive Control; Immunogen; SDS-PAGE; WB.
APC907Hu01 Active Fibroblast Growth Factor 18 (FGF18) Cell culture; Activity Assays.
PAC907Hu01 Polyclonal Antibody to Fibroblast Growth Factor 18 (FGF18) WB; IHC; ICC; IP.
MAC907Hu22 Monoclonal Antibody to Fibroblast Growth Factor 18 (FGF18) WB; IHC; ICC; IP.
SEC907Hu ELISA Kit for Fibroblast Growth Factor 18 (FGF18) Enzyme-linked immunosorbent assay for Antigen Detection.
CEC907Hu ELISA Kit for Fibroblast Growth Factor 18 (FGF18) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC907Hu CLIA Kit for Fibroblast Growth Factor 18 (FGF18) Chemiluminescent immunoassay for Antigen Detection.
CCC907Hu CLIA Kit for Fibroblast Growth Factor 18 (FGF18) Chemiluminescent immunoassay for Antigen Detection.
LMC907Hu Multiplex Assay Kit for Fibroblast Growth Factor 18 (FGF18) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK