CLIA Kit for Complement 1 Inhibitor (C1INH)

SERPING1; C1IN; C1-INH; C1NH; HAE1; HAE2; Serpin Peptidase Inhibitor Clade G Member 1; Angioedema Hereditary; C1 Inhibitor; C1 Esterase Inhibitor

  • CLIA Kit for Complement 1 Inhibitor (C1INH) Packages (Simulation)
  • CLIA Kit for Complement 1 Inhibitor (C1INH) Packages (Simulation)
  • CLIA Kit for Complement 1 Inhibitor (C1INH) Results demonstration
  • SCA235Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Complement 1 Inhibitor (C1INH)

This assay has high sensitivity and excellent specificity for detection of Complement 1 Inhibitor (C1INH).
No significant cross-reactivity or interference between Complement 1 Inhibitor (C1INH) and analogues was observed.

Recovery of the CLIA Kit for Complement 1 Inhibitor (C1INH)

Matrices listed below were spiked with certain level of recombinant Complement 1 Inhibitor (C1INH) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement 1 Inhibitor (C1INH) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-97 91
EDTA plasma(n=5) 94-101 98
heparin plasma(n=5) 93-104 98

Precision of the CLIA Kit for Complement 1 Inhibitor (C1INH)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement 1 Inhibitor (C1INH) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement 1 Inhibitor (C1INH) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Complement 1 Inhibitor (C1INH)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement 1 Inhibitor (C1INH) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-93% 78-97% 82-94% 79-103%
EDTA plasma(n=5) 87-103% 87-103% 89-96% 96-103%
heparin plasma(n=5) 98-105% 78-97% 87-95% 81-96%

Stability of the CLIA Kit for Complement 1 Inhibitor (C1INH)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Complement 1 Inhibitor (C1INH)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Complement 1 Inhibitor (C1INH)

The microplate provided in this kit has been pre-coated with an antibody specific to Complement 1 Inhibitor (C1INH). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Complement 1 Inhibitor (C1INH). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Complement 1 Inhibitor (C1INH) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA235Hu01 Recombinant Complement 1 Inhibitor (C1INH) Positive Control; Immunogen; SDS-PAGE; WB.
RPA235Hu02 Recombinant Complement 1 Inhibitor (C1INH) Positive Control; Immunogen; SDS-PAGE; WB.
PAA235Hu01 Polyclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC; IP.
PAA235Hu02 Polyclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC; IP.
LAA235Hu71 Biotin-Linked Polyclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC.
LAA235Hu81 FITC-Linked Polyclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC; IF.
MAA235Hu21 Monoclonal Antibody to Complement 1 Inhibitor (C1INH) WB
MAA235Hu22 Monoclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC; IP.
MAA235Hu23 Monoclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC; IP.
LAA235Hu72 Biotin-Linked Monoclonal Antibody to Complement 1 Inhibitor (C1INH) WB; IHC; ICC.
SEA235Hu ELISA Kit for Complement 1 Inhibitor (C1INH) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA235Hu CLIA Kit for Complement 1 Inhibitor (C1INH) Chemiluminescent immunoassay for Antigen Detection.
LMA235Hu Multiplex Assay Kit for Complement 1 Inhibitor (C1INH) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK