CLIA Kit for Calcitonin Gene Related Peptide (CGRP)

CALCB; CGRP2; CALC2; CGRP-II; Calcitonin Gene Related Peptide 2; Calcitonin 2; Calcitonin Related Polypeptide Beta

  • CLIA Kit for Calcitonin Gene Related Peptide (CGRP) Packages (Simulation)
  • CLIA Kit for Calcitonin Gene Related Peptide (CGRP) Packages (Simulation)
  • CLIA Kit for Calcitonin Gene Related Peptide (CGRP) Results demonstration
  • CCA876Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Calcitonin Gene Related Peptide (CGRP)

This assay has high sensitivity and excellent specificity for detection of Calcitonin Gene Related Peptide (CGRP).
No significant cross-reactivity or interference between Calcitonin Gene Related Peptide (CGRP) and analogues was observed.

Recovery of the CLIA Kit for Calcitonin Gene Related Peptide (CGRP)

Matrices listed below were spiked with certain level of recombinant Calcitonin Gene Related Peptide (CGRP) and the recovery rates were calculated by comparing the measured value to the expected amount of Calcitonin Gene Related Peptide (CGRP) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-104 96
EDTA plasma(n=5) 98-105 102
heparin plasma(n=5) 88-102 95

Precision of the CLIA Kit for Calcitonin Gene Related Peptide (CGRP)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Calcitonin Gene Related Peptide (CGRP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Calcitonin Gene Related Peptide (CGRP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Calcitonin Gene Related Peptide (CGRP)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Calcitonin Gene Related Peptide (CGRP) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-98% 99-105% 78-99% 90-102%
EDTA plasma(n=5) 94-101% 79-103% 79-90% 79-94%
heparin plasma(n=5) 83-91% 80-88% 81-95% 98-105%

Stability of the CLIA Kit for Calcitonin Gene Related Peptide (CGRP)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Calcitonin Gene Related Peptide (CGRP)

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.

Test principle of the CLIA Kit for Calcitonin Gene Related Peptide (CGRP)

The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Calcitonin Gene Related Peptide (CGRP). A competitive inhibition reaction is launched between biotin labeled Calcitonin Gene Related Peptide (CGRP) and unlabeled Calcitonin Gene Related Peptide (CGRP) (Standards or samples) with the pre-coated antibody specific to Calcitonin Gene Related Peptide (CGRP). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Calcitonin Gene Related Peptide (CGRP) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Calcitonin Gene Related Peptide (CGRP) level in the sample or standard.

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
APA876Ra01 Active Calcitonin Gene Related Peptide (CGRP) Cell culture; Activity Assays.
RPA876Ra01 Recombinant Calcitonin Gene Related Peptide (CGRP) Positive Control; Immunogen; SDS-PAGE; WB.
CPA876Ra21 OVA Conjugated Calcitonin Gene Related Peptide (CGRP) Immunogen; SDS-PAGE; WB.
PAA876Ra01 Polyclonal Antibody to Calcitonin Gene Related Peptide (CGRP) WB; IHC; ICC; IP.
MAA876Ra21 Monoclonal Antibody to Calcitonin Gene Related Peptide (CGRP) WB; IHC; ICC; IP.
CEA876Ra ELISA Kit for Calcitonin Gene Related Peptide (CGRP) Enzyme-linked immunosorbent assay for Antigen Detection.
CCA876Ra CLIA Kit for Calcitonin Gene Related Peptide (CGRP) Chemiluminescent immunoassay for Antigen Detection.
LMA876Ra Multiplex Assay Kit for Calcitonin Gene Related Peptide (CGRP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.