CLIA Kit for B-Lymphocyte Chemoattractant (BLC)

CXCL13; SCYB13; BCA1; BLR1L; ANGIE; ANGIE2; Chemokine(C-X-C-Motif)ligand 13; Small Inducible Cytokine B Subfamily(Cys-X-Cys Motif)Member 13

  • CLIA Kit for B-Lymphocyte Chemoattractant (BLC) Packages (Simulation)
  • CLIA Kit for B-Lymphocyte Chemoattractant (BLC) Packages (Simulation)
  • CLIA Kit for B-Lymphocyte Chemoattractant (BLC) Results demonstration
  • SCB601Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for B-Lymphocyte Chemoattractant (BLC)

This assay has high sensitivity and excellent specificity for detection of B-Lymphocyte Chemoattractant (BLC).
No significant cross-reactivity or interference between B-Lymphocyte Chemoattractant (BLC) and analogues was observed.

Recovery of the CLIA Kit for B-Lymphocyte Chemoattractant (BLC)

Matrices listed below were spiked with certain level of recombinant B-Lymphocyte Chemoattractant (BLC) and the recovery rates were calculated by comparing the measured value to the expected amount of B-Lymphocyte Chemoattractant (BLC) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-94 91
EDTA plasma(n=5) 78-91 88
heparin plasma(n=5) 89-99 95

Precision of the CLIA Kit for B-Lymphocyte Chemoattractant (BLC)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level B-Lymphocyte Chemoattractant (BLC) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level B-Lymphocyte Chemoattractant (BLC) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for B-Lymphocyte Chemoattractant (BLC)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of B-Lymphocyte Chemoattractant (BLC) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-99% 87-95% 87-101% 88-97%
EDTA plasma(n=5) 82-98% 85-94% 95-104% 93-105%
heparin plasma(n=5) 94-105% 80-101% 95-104% 83-97%

Stability of the CLIA Kit for B-Lymphocyte Chemoattractant (BLC)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for B-Lymphocyte Chemoattractant (BLC)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for B-Lymphocyte Chemoattractant (BLC)

The microplate provided in this kit has been pre-coated with an antibody specific to B-Lymphocyte Chemoattractant (BLC). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to B-Lymphocyte Chemoattractant (BLC). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the B-Lymphocyte Chemoattractant (BLC) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APB601Hu01 Active B-Lymphocyte Chemoattractant (BLC) Cell culture; Activity Assays.
RPB601Hu01 Recombinant B-Lymphocyte Chemoattractant (BLC) Positive Control; Immunogen; SDS-PAGE; WB.
PAB601Hu01 Polyclonal Antibody to B-Lymphocyte Chemoattractant (BLC) WB,IHC
MAB601Hu22 Monoclonal Antibody to B-Lymphocyte Chemoattractant (BLC) WB; IHC; ICC; IP.
SEB601Hu ELISA Kit for B-Lymphocyte Chemoattractant (BLC) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB601Hu CLIA Kit for B-Lymphocyte Chemoattractant (BLC) Chemiluminescent immunoassay for Antigen Detection.
LMB601Hu Multiplex Assay Kit for B-Lymphocyte Chemoattractant (BLC) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK