CLIA Kit for Amyloid Precursor Protein (APP)

AAA; ABeta; ABPP; AD1; APPI; CVAP; PN2; CTFgamma; Peptidase Nexin-II Alzheimer Disease; Peptidase Nexin-II; Amyloid Beta(A4)Precursor Protein

  • CLIA Kit for Amyloid Precursor Protein (APP) Packages (Simulation)
  • CLIA Kit for Amyloid Precursor Protein (APP) Packages (Simulation)
  • CLIA Kit for Amyloid Precursor Protein (APP) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Amyloid Precursor Protein (APP)

This assay has high sensitivity and excellent specificity for detection of Amyloid Precursor Protein (APP).
No significant cross-reactivity or interference between Amyloid Precursor Protein (APP) and analogues was observed.

Recovery of the CLIA Kit for Amyloid Precursor Protein (APP)

Matrices listed below were spiked with certain level of recombinant Amyloid Precursor Protein (APP) and the recovery rates were calculated by comparing the measured value to the expected amount of Amyloid Precursor Protein (APP) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-102 98
EDTA plasma(n=5) 92-101 96
heparin plasma(n=5) 79-90 83

Precision of the CLIA Kit for Amyloid Precursor Protein (APP)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Amyloid Precursor Protein (APP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Amyloid Precursor Protein (APP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Amyloid Precursor Protein (APP)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Amyloid Precursor Protein (APP) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 82-93% 93-101% 97-105%
EDTA plasma(n=5) 98-105% 81-102% 97-105% 92-105%
heparin plasma(n=5) 79-101% 94-102% 93-104% 84-101%

Stability of the CLIA Kit for Amyloid Precursor Protein (APP)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Amyloid Precursor Protein (APP)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Amyloid Precursor Protein (APP)

The microplate provided in this kit has been pre-coated with an antibody specific to Amyloid Precursor Protein (APP). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Amyloid Precursor Protein (APP). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Amyloid Precursor Protein (APP) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPB020Hu02 Recombinant Amyloid Precursor Protein (APP) Positive Control; Immunogen; SDS-PAGE; WB.
RPB020Hu03 Recombinant Amyloid Precursor Protein (APP) Positive Control; Immunogen; SDS-PAGE; WB.
RPB020Hu01 Recombinant Amyloid Precursor Protein (APP) Positive Control; Immunogen; SDS-PAGE; WB.
PAB020Hu01 Polyclonal Antibody to Amyloid Precursor Protein (APP) WB; IHC; ICC; IP.
PAB020Hu02 Polyclonal Antibody to Amyloid Precursor Protein (APP) WB; IHC; ICC; IP.
PAB020Hu03 Polyclonal Antibody to Amyloid Precursor Protein (APP) WB; IHC; ICC; IP.
MAB020Hu22 Monoclonal Antibody to Amyloid Precursor Protein (APP) WB; IHC; ICC; IP.
MAB020Hu23 Monoclonal Antibody to Amyloid Precursor Protein (APP) WB; IHC; ICC; IP.
WEB020Hu Wide-range ELISA Kit for Amyloid Precursor Protein (APP) Enzyme-linked immunosorbent assay for Antigen Detection.
SEB020Hu ELISA Kit for Amyloid Precursor Protein (APP) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB020Hu CLIA Kit for Amyloid Precursor Protein (APP) Chemiluminescent immunoassay for Antigen Detection.
LMB020Hu Multiplex Assay Kit for Amyloid Precursor Protein (APP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.