CLIA Kit for Receptor For Advanced Glycation Endproducts (RAGE)

AGER; Receptor For Advanced Glycation Endproducts

  • CLIA Kit for Receptor For Advanced Glycation Endproducts (RAGE) Packages (Simulation)
  • CLIA Kit for Receptor For Advanced Glycation Endproducts (RAGE) Packages (Simulation)
  • CLIA Kit for Receptor For Advanced Glycation Endproducts (RAGE) Results demonstration
  • SCA645Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Receptor For Advanced Glycation Endproducts (RAGE)

This assay has high sensitivity and excellent specificity for detection of Receptor For Advanced Glycation Endproducts (RAGE).
No significant cross-reactivity or interference between Receptor For Advanced Glycation Endproducts (RAGE) and analogues was observed.

Recovery of the CLIA Kit for Receptor For Advanced Glycation Endproducts (RAGE)

Matrices listed below were spiked with certain level of recombinant Receptor For Advanced Glycation Endproducts (RAGE) and the recovery rates were calculated by comparing the measured value to the expected amount of Receptor For Advanced Glycation Endproducts (RAGE) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-92 87
EDTA plasma(n=5) 84-101 95
heparin plasma(n=5) 80-93 89

Precision of the CLIA Kit for Receptor For Advanced Glycation Endproducts (RAGE)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Receptor For Advanced Glycation Endproducts (RAGE) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Receptor For Advanced Glycation Endproducts (RAGE) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Receptor For Advanced Glycation Endproducts (RAGE)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Receptor For Advanced Glycation Endproducts (RAGE) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-102% 93-105% 78-105% 81-97%
EDTA plasma(n=5) 78-93% 90-101% 98-105% 95-102%
heparin plasma(n=5) 94-103% 95-102% 82-98% 95-102%

Stability of the CLIA Kit for Receptor For Advanced Glycation Endproducts (RAGE)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Receptor For Advanced Glycation Endproducts (RAGE)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Receptor For Advanced Glycation Endproducts (RAGE)

The microplate provided in this kit has been pre-coated with an antibody specific to Receptor For Advanced Glycation Endproducts (RAGE). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Receptor For Advanced Glycation Endproducts (RAGE). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Receptor For Advanced Glycation Endproducts (RAGE) level in the sample or standard.;

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA645Mu02 Recombinant Receptor For Advanced Glycation Endproducts (RAGE) Positive Control; Immunogen; SDS-PAGE; WB.
RPA645Mu01 Recombinant Receptor For Advanced Glycation Endproducts (RAGE) Positive Control; Immunogen; SDS-PAGE; WB.
PAA645Mu01 Polyclonal Antibody to Receptor For Advanced Glycation Endproducts (RAGE) WB; IHC; ICC; IP.
PAA645Mu02 Polyclonal Antibody to Receptor For Advanced Glycation Endproducts (RAGE) WB; IHC; ICC; IP.
SEA645Mu ELISA Kit for Receptor For Advanced Glycation Endproducts (RAGE) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA645Mu CLIA Kit for Receptor For Advanced Glycation Endproducts (RAGE) Chemiluminescent immunoassay for Antigen Detection.
LMA645Mu Multiplex Assay Kit for Receptor For Advanced Glycation Endproducts (RAGE) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK